Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
flammable solids
Type of information:
experimental study
Adequacy of study:
key study
Study period:
31 January 2018 - 27 February 2018
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study
Qualifier:
according to guideline
Guideline:
EU Method A.10 (Flammability (Solids))
Deviations:
no
GLP compliance:
yes (incl. QA statement)
Test procedure:
burning rate test: preliminary screening test
Burning time:
>= 4 min
Remarks on result:
substance does not ignite and propagate combustion either by burning with flame or smouldering along 200 mm of the powder train within the 2 minutes test period
Remarks:
The test item ignited during the two minutes of application of the burner and the flame subsequently propagated along the train for a distance of 110 mm but did not burn the full distance of 200 mm within the time of 4 minutes.

The test item ignited during the two minutes of application of the burner and the flame subsequently propagated along the train for a distance of 110 mm but did not burn the full distance of 200 mm within the time of 4 minutes.

Interpretation of results:
not classified based on GHS criteria
Conclusions:
The test item ignited during the two minutes of application of the burner and the flame subsequently propagated along the train for a distance of 110 mm but did not burn the full distance of 200 mm within the time of 4 minutes in the preliminary test, therefore no further testing was necessary. The test item was not highly flammable.
Executive summary:

The flammability of the test item was investigated in an EC Method A.10 study. In the preliminary test, the test item ignited during the two minutes of application of the burner and the flame subsequently propagated along the train for a distance of 110 mm but did not burn the full distance of 200 mm within the time of 4 minutes, therefore no further testing was necessary. The test item was not highly flammable.

The study is a GLP compliant, guideline experimental study and is fully acceptable for assessment of this endpoint.

Description of key information

In the preliminary test, the test item ignited during the two minutes of application of the burner and the flame subsequently propagated along the train for a distance of 110 mm but did not burn the full distance of 200 mm within the time of 4 minutes, therefore no further testing was necessary. The test item was not highly flammable.

Key value for chemical safety assessment

Flammability:
not classified

Additional information

The flammability of the test item was investigated in a GLP compliant EC Method A.10 study that is fully acceptable for assessment of this endpoint.

Justification for classification or non-classification

In the preliminary test, the test item ignited during the two minutes of application of the burner and the flame subsequently propagated along the train for a distance of 110 mm but did not burn the full distance of 200 mm within the time of 4 minutes, therefore no further testing was necessary. The test item was not highly flammable.