Registration Dossier

Diss Factsheets

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
flammable solids
Type of information:
experimental study
Adequacy of study:
key study
Study period:
2018-01-31 to 2018-05-17
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study
Qualifier:
according to guideline
Guideline:
EU Method A.10 (Flammability (Solids))
GLP compliance:
no
Key result
Test procedure:
burning rate test: preliminary screening test
Remarks on result:
substance does not ignite and propagate combustion either by burning with flame or smouldering along 200 mm of the powder train within the 2 minutes test period

During the preliminary test the test item could not be ignited with a flame. The test item melted. Thus, the performance of the main test was not necessary.

Interpretation of results:
GHS criteria not met
Conclusions:
The test item is not a highly flammable solid in the sense of the European Commission Regulation (EC) No. 440/2008, Method A.10.
Executive summary:

During the preliminary test the test item could not be ignited with a flame. The test item melted. Thus, the performance of the main test was not necessary. The test item is not a highly flammable solid in the sense of the European Commission Regulation (EC) No. 440/2008, Method A.10.

Description of key information

The test item is not a highly flammable solid in the sense of the European Commission Regulation (EC) No. 440/2008, Method A.10

Key value for chemical safety assessment

Flammability:
not classified

Additional information

During the preliminary test the test item could not be ignited with a flame. The test item melted. Thus, the performance of the main test was not necessary.

Justification for classification or non-classification