Registration Dossier

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
oxidising liquids
Type of information:
calculation (if not (Q)SAR)
Adequacy of study:
key study
Reliability:
2 (reliable with restrictions)
Rationale for reliability incl. deficiencies:
accepted calculation method
Justification for type of information:
Assessment based on chemical composition and structure of components
Qualifier:
according to guideline
Guideline:
EU Method A.21 (Oxidising Properties (Liquids))
Principles of method if other than guideline:
Assessment based on chemical composition and structure of components
GLP compliance:
no
Specific details on test material used for the study:
Performed as assessment based on chemical composition and structure of components. Test material not handled
Sample tested:
other: Assessment method
Parameter:
other: Assessment
Remarks on result:
other: Estimated negative

Predicted negative based on the chemical structure of the test item, using a procedure designed to be compatible with Method A.21 Oxidising Properties (Liquids) of Commission Regulation (EC) No 440/2008 of 30 May 2008.

Interpretation of results:
GHS criteria not met
Conclusions:
Predicted negative based on the chemical structure and composition of the test item

Description of key information

Predicted negative based on the chemical structure and composition of the test item

Key value for chemical safety assessment

Oxidising properties:
non oxidising

Additional information

Justification for classification or non-classification