Registration Dossier

Physical & Chemical properties

Flammability

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
substances / mixtures which in contact with water emit flammable gases
Type of information:
experimental study
Adequacy of study:
key study
Study period:
The study was conducted between 24 January 2018 and 26 January 2018.
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
other: The study is considered to be a reliability 1 as it has been conducted according to EU-A12 guidelines and in compliance with GLP.
Qualifier:
according to guideline
Guideline:
EU Method A.12 (Flammability (Contact with Water))
GLP compliance:
yes (incl. QA statement)
Specific details on test material used for the study:
Identification: FRET 11-0539
Appearance/Physical state: Clear colorless liquid
Storage conditions: Room temperature in the dark
Test procedure:
step 1
step 2
step 3
step 4
Identity of evolved gas:
not applicable as no gas evolved
Remarks on result:
no reaction with water observed

The results of the steps are shown in the following table:

Step

Observations

Step 1

The test item spread across the surface of the water. No gas evolved.

Step 2

The test item spread slightly over the surface of the filter paper. No gas evolved.

Step 3

The water sank through the test item and collected as a droplet. No gas evolved.

Step 4

Replicate 1

No gas evolved over the 7 hours.

Replicate 2

No gas evolved over the 7 hours.

Replicate 3

No gas evolved over the 7 hours.

Interpretation of results:
GHS criteria not met
Conclusions:
Substance FRET 11-0539 was found not be flammable using a reliable GLP study according to EU Method A.12 (Flammability (Contact with Water)) in compliance with GLP.
Executive summary:

Substance FRET 11-0539 was found not be flammable using a reliable GLP study according to EU Method A.12 (Flammability (Contact with Water)).

Description of key information

 Substance FRET 11-0539 was found not be flammable using a reliable GLP study according to EU Method A.12  (Flammability (Contact with Water)) in compliance with GLP.

Key value for chemical safety assessment

Flammability:
not classified

Additional information

Justification for classification or non-classification

Based on the above mentioned result, classification according to the CLP Regulation (EC) No. 1272/2008 and the Dangerous Substance Directive 67/548/EC is not necessary.