Registration Dossier
Registration Dossier
Diss Factsheets
Use of this information is subject to copyright laws and may require the permission of the owner of the information, as described in the ECHA Legal Notice.
EC number: 202-632-4 | CAS number: 98-06-6
- Life Cycle description
- Uses advised against
- Endpoint summary
- Appearance / physical state / colour
- Melting point / freezing point
- Boiling point
- Density
- Particle size distribution (Granulometry)
- Vapour pressure
- Partition coefficient
- Water solubility
- Solubility in organic solvents / fat solubility
- Surface tension
- Flash point
- Auto flammability
- Flammability
- Explosiveness
- Oxidising properties
- Oxidation reduction potential
- Stability in organic solvents and identity of relevant degradation products
- Storage stability and reactivity towards container material
- Stability: thermal, sunlight, metals
- pH
- Dissociation constant
- Viscosity
- Additional physico-chemical information
- Additional physico-chemical properties of nanomaterials
- Nanomaterial agglomeration / aggregation
- Nanomaterial crystalline phase
- Nanomaterial crystallite and grain size
- Nanomaterial aspect ratio / shape
- Nanomaterial specific surface area
- Nanomaterial Zeta potential
- Nanomaterial surface chemistry
- Nanomaterial dustiness
- Nanomaterial porosity
- Nanomaterial pour density
- Nanomaterial photocatalytic activity
- Nanomaterial radical formation potential
- Nanomaterial catalytic activity
- Endpoint summary
- Stability
- Biodegradation
- Bioaccumulation
- Transport and distribution
- Environmental data
- Additional information on environmental fate and behaviour
- Ecotoxicological Summary
- Aquatic toxicity
- Endpoint summary
- Short-term toxicity to fish
- Long-term toxicity to fish
- Short-term toxicity to aquatic invertebrates
- Long-term toxicity to aquatic invertebrates
- Toxicity to aquatic algae and cyanobacteria
- Toxicity to aquatic plants other than algae
- Toxicity to microorganisms
- Endocrine disrupter testing in aquatic vertebrates – in vivo
- Toxicity to other aquatic organisms
- Sediment toxicity
- Terrestrial toxicity
- Biological effects monitoring
- Biotransformation and kinetics
- Additional ecotoxological information
- Toxicological Summary
- Toxicokinetics, metabolism and distribution
- Acute Toxicity
- Irritation / corrosion
- Sensitisation
- Repeated dose toxicity
- Genetic toxicity
- Carcinogenicity
- Toxicity to reproduction
- Specific investigations
- Exposure related observations in humans
- Toxic effects on livestock and pets
- Additional toxicological data

Adsorption / desorption
Administrative data
Link to relevant study record(s)
- Endpoint:
- adsorption / desorption: screening
- Type of information:
- experimental study
- Adequacy of study:
- key study
- Study period:
- 2019
- Reliability:
- 1 (reliable without restriction)
- Rationale for reliability incl. deficiencies:
- guideline study
- Qualifier:
- according to guideline
- Guideline:
- OECD Guideline 121 (Estimation of the Adsorption Coefficient (Koc) on Soil and on Sewage Sludge using High Performance Liquid Chromatography (HPLC))
- Version / remarks:
- Adopted 22. Jan. 2001
- Deviations:
- no
- Qualifier:
- according to guideline
- Guideline:
- EU Method C.19 (Estimation of the Adsorption Coefficient (KOC) on Soil and Sewage Sludge Using High Performance Liquid Chromatography (HPLC))
- Version / remarks:
- Council Regulation (EC) No 440/2008 of 30 May 2008
- Deviations:
- no
- GLP compliance:
- yes (incl. QA statement)
- Type of method:
- HPLC estimation method
- Media:
- soil/sewage sludge
- Specific details on test material used for the study:
- Batch no.: DJ3901A19018
Storage: Room Temperature (20 ± 5°C) - Radiolabelling:
- no
- Test temperature:
- 25 ± 0.5 °C
- Details on study design: HPLC method:
- -HPLC_6
Components: Solvent Rack, Pump LPG-3400SD, Autosampler WPS-3000TSL, Column Compartment TCC-3200 with 6-fold column switch valve UV-Detector MWD-3000
Manufacturer: Thermo Fisher Scientific
Software: CHROMELEON 6.80 SR15b Build 4981
Usage and calibration followed the corresponding SOP 114 00 529 in the current edition
-Method parameters HPLC
Column: Reprosil Pur CN 150*4.6 mm, 5μm with guard column Phenomenex SecurityGuard CN, 4*3 mm
Eluent: isocratic methanol/water 55/45 (% v/v), degassed
Flow rate: 0.8 mL/min
Injection volume: 10 μL
Column temperature: 25.0 ± 0.5 °C.
Wavelength for evaluation: 210 nm (reference item mix), 254 nm (test item)
-MOBILE PHASES
- Type: A mixture of 55% methanol and 45% water, isocratic, was used.
- Experiments with additives carried out on separate columns: no
- pH: 6-7
- Solutes for dissolving test and reference substances: A solution of the test item was prepared by weighing 20.0 mg tert-Butylbenzene into a 20 mL flask and filling up to 20.0 mL with methanol (HPLC Grade) 550 μL of this solution were mixed with 450μL water (HPLC grade), resulting in a solution with a concentration of 550.0 mg/L which was used for the measurements.
DETERMINATION OF DEAD TIME
- Method: by inert substances which are not retained by the column (Dead time marker: Sodium nitrate (CAS#7631-99-4))
REFERENCE SUBSTANCES
- Identity:Sodium nitrate (CAS#7631-99-4), Acetanilid (CAS#103-84-4), Methylbenzoate (CAS#93-58-3), Naphthalene (CAS#91-20-3), 1,2,3-Trichlor-benzene (CAS#87-61-6), Phenanthrene (CAS#85-01-8), 4,4’-DDT (CAS#50-29-3)
DETERMINATION OF RETENTION TIMES
- Quantity of test substance introduced in the column: 3
- Quantity of reference substances: 6
REPETITIONS
- Number of determinations: 3
EVALUATION
- Calculation of capacity factors k': k'=(tr-t0)/t0 with tr: retention time, t0: dead time (retention time of sodium nitrate)
- Calculation of retention times: Mean
- Determination of the log Koc value: With the calculated capacity factors for the test item, each log KOC from the three determinations was calculated. Finally, mean and standard deviation of the log KOC were calculated. - Details on sampling:
- - Concentrations: 550.0 mg/L
- Sample storage before analysis: Stored in the test facility in a closed vessel at room temperature (20 ± 5 °C). - Key result
- Sample No.:
- #1
- Type:
- log Koc
- Value:
- ca. 2.888 dimensionless
- pH:
- 6
- Temp.:
- 25 °C
- Key result
- Sample No.:
- #2
- Type:
- log Koc
- Value:
- ca. 2.888 dimensionless
- pH:
- 6
- Temp.:
- 25 °C
- Key result
- Sample No.:
- #3
- Type:
- log Koc
- Value:
- ca. 2.888 dimensionless
- pH:
- 6
- Temp.:
- 25 °C
- Details on results (HPLC method):
- - Retention times of reference substances used for calibration: 1.024
- Details of fitted regression line (log k' vs. log Koc): log k’ = 0.1948 * logKOC – 0.1363 with a coefficient of determination r2 = 0.9674.
- Average retention data for test substance: 3.757 - Validity criteria fulfilled:
- yes
- Conclusions:
- Using the correlation log k’ / log KOC, the log KOC of the peak of the test item tert-Butylbenzene was calculated as 2.888 ± 0.000 (mean ± standard deviation) at a temperature of 25 ± 0.5 °C and a pH value of 6-7 (measured with pH paper).
- Executive summary:
Variations in the retention times of reference items and test item are very small. Therefore, a stable configuration of the HPLC-column can be assumed.
The correlation log k’/log KOC is sufficiently accurate, as calibration gave a coefficient of determination r2 = 0.9674.
The chromatogram of the test item gave one peak (mean RT = 3.757 min). With the calibra-tion function log k’ versus log KOC, the corresponding log KOC could be calculated as
2.888 ± 0.000 (mean ± sd).
Therefore, the log KOC of the test item tert-Butylbenzene is stated as 2.89 (mean) at a temperature of 25 ± 0.5 °C and a pH value of 6-7 (measured with pH paper).
No observations were made which might give doubts concerning the validity of the study outcome.
Reference
Description of key information
Key value for chemical safety assessment
- Koc at 20 °C:
- 758.579
Additional information
log Koc=2.888 ± 0.000 (mean ± sd) at 25 °C
Information on Registered Substances comes from registration dossiers which have been assigned a registration number. The assignment of a registration number does however not guarantee that the information in the dossier is correct or that the dossier is compliant with Regulation (EC) No 1907/2006 (the REACH Regulation). This information has not been reviewed or verified by the Agency or any other authority. The content is subject to change without prior notice.
Reproduction or further distribution of this information may be subject to copyright protection. Use of the information without obtaining the permission from the owner(s) of the respective information might violate the rights of the owner.