Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Physical & Chemical properties

Flash point

Currently viewing:

Administrative data

Endpoint:
flash point, other
Type of information:
(Q)SAR
Adequacy of study:
key study
Reliability:
3 (not reliable)
Rationale for reliability incl. deficiencies:
results derived from a valid (Q)SAR model, but not (completely) falling into its applicability domain, and documentation / justification is limited
Justification for type of information:
Software tool(s) used including version: ACD/Labs Percepta Platform - PhysChem Module

Data source

Reference
Reference Type:
review article or handbook
Title:
ChemSpider database - Hematoxylin Information
Author:
Royal Society of Chemistry
Year:
2011
Bibliographic source:
Oxford University Chemical Safety Data (No longer updated)
Report date:
2011

Materials and methods

Principles of method if other than guideline:
- Software tool(s) used including version: ACD/Labs Percepta Platform - PhysChem Module
GLP compliance:
no

Test material

Constituent 1
Chemical structure
Reference substance name:
Haematoxylin
EC Number:
208-237-3
EC Name:
Haematoxylin
Cas Number:
517-28-2
Molecular formula:
C16H14O6
IUPAC Name:
haematoxylin

Results and discussion

Flash point
Key result
Flash point:
ca. 304.5 °C
Atm. press.:
ca. 1 atm

Applicant's summary and conclusion

Interpretation of results:
GHS criteria not met
Conclusions:
The calculated flash point is 304.5±30.1 °C.