Administrative data

Link to relevant study record(s)

Reference
Endpoint:
flash point of flammable liquids
Type of information:
experimental study
Adequacy of study:
key study
Study period:
2017-03-02
Reliability:
1 (reliable without restriction)
Qualifier:
according to guideline
Guideline:
EU Method A.9 (Flash-Point)
Deviations:
no
GLP compliance:
no
Type of method:
non-equilibrium method closed cup
Flash point apparatus:
Pensky-Martens apparatus
Key result
Flash point:
198 °C
Atm. press.:
1 013 hPa

Preliminary test

Test item / g

Starting temperature /°C

Temperature /°C

Ignition + / -

4

100

202

+

4

100

200

+

4

180

202

+

 

Main test

Test item / g

Temperature /°C

Ignition + / -

Barometric pressure / hPa

4

200.0

+

1005.5

4

195.0

-

1005.5

4

196.0

-

1005.5

4

197.0

-

1005.5

4

198.0

-

1005.5

4

199.0

+

1005.5

4

198.0

+

1005.5

4

197.0

-

1005.5

4

197.5

-

1005.5

4

198.0

+

1005.5

4

197.5

-

1005.5

4

198.0

+

1005.5

4

197.5

-

1005.5

 

The lowest flash point corrected to 1013 hPa is rounded down with an accuracy of 0.5 °C: 198.0 °C.

Interpretation of results:
GHS criteria not met
Conclusions:
The flash point of the test item was determined to be 198.0 °C (corrected and rounded down to the nearest multiple of 0.5 °C) at 1013.25 hPa.
Executive summary:

A study was conducted according to Regulation (EC) No 440/2008 method A.9 to determine flash point of the test item using a closed cup method (reference 4.11 -1). The start temperature for the main test (200 °C) was chosen based on the preliminary test. Therefore 4 mL of the test item are filled in the cup and heated to the estimated temperature. Then the substance was maintained for at least 1 minute at this temperature. The flame was dipped in the cup and it was checked if ignition occurred. The measured flash point at atmospheric pressure was corrected to a standard pressure of 1013 hPa. The flash point was determined to be at 198.0 °C (corrected to the ambient pressure). Thus, the flash point of the test item was determined to be 198.0°C (corrected and rounded down to the nearest multiple of 0.5 °C) at 1013.25 hPa.

Description of key information

The flash point of the test item was determined to be 198.0 °C (corrected and rounded down to the nearest multiple of 0.5 °C) at 1013.25 hPa.

Key value for chemical safety assessment

Flash point at 101 325 Pa:
198 °C

Additional information

A study was conducted according to Regulation (EC) No 440/2008 method A.9 to determine flash point of the test item using a closed cup method (reference 4.11 -1). The start temperature for the main test (200 °C) was chosen based on the preliminary test. Therefore 4 mL of the test item are filled in the cup and heated to the estimated temperature. Then the substance was maintained for at least 1 minute at this temperature. The flame was dipped in the cup and it was checked if ignition occurred. The measured flash point at atmospheric pressure was corrected to a standard pressure of 1013 hPa. The flash point was determined to be at 198.0 °C (corrected to the ambient pressure). Thus, the flash point of the test item was determined to be 198.0°C (corrected and rounded down to the nearest multiple of 0.5 °C) at 1013.25 hPa.