Registration Dossier

Diss Factsheets

Physical & Chemical properties

Flash point

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
flash point of flammable liquids
Type of information:
experimental study
Adequacy of study:
key study
Study period:
Jul 27 - Aug 09, 2016
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study
Qualifier:
according to guideline
Guideline:
ISO 2719 (Determination of flash point - Pensky-Martens closed cup method)
GLP compliance:
yes
Type of method:
closed cup
Flash point apparatus:
Pensky-Martens apparatus
Flash point:
130 °C
Atm. press.:
101.8 kPa

Detailed Flash Point Test Results:

Temperature (°C)

Barometric Pressure (kPa)

Ignition? Yes (y) / No (n)

Halo/Enlarged test flame? Yes (y) / No (n)

Run 1

107-120

101.8

n

n

121-131

101.8

n

y

132

101.8

y

n

Run 2

109-120

101.8

n

n

121-129

101.8

n

y

130

101.8

y

n

Description of key information

130 °C closed cup at ca. 101.3 kPa (ISO 2719)

Key value for chemical safety assessment

Flash point at 101 325 Pa:
130 °C

Additional information