Administrative data

Endpoint:
flash point of flammable liquids
Type of information:
experimental study
Adequacy of study:
key study
Study period:
07 March - 16 September 2017
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
2018
Report date:
2018

Materials and methods

Test guidelineopen allclose all
Qualifier:
according to guideline
Guideline:
EU Method A.9 (Flash-Point)
Deviations:
no
Qualifier:
according to guideline
Guideline:
ASTM D93 (Standard test methods for flash point by pensky-martens closed cup tester)
Deviations:
no
Qualifier:
according to guideline
Guideline:
other: (UN no. ST/SG/AC.10/11/Rev.6 (Non-Viscous Flammable Liquids)
Deviations:
no
Qualifier:
according to guideline
Guideline:
ISO 2719 (Determination of flash point - Pensky-Martens closed cup method)
Deviations:
no
Qualifier:
according to guideline
Guideline:
other: ASTM D7094 (Standard Test Method for Flash Point by Modified Continuously Closed Cup (MCCCFP) Tester)
Deviations:
no
GLP compliance:
yes (incl. QA statement)
Type of method:
closed cup
Flash point apparatus:
other: Eraflash flash-point tester (Eralytics, Vienna, Austria)

Test material

1
Chemical structure
Reference substance name:
(2S)-6-fluoro-2-(oxiran-2-yl)chromane
EC Number:
930-889-9
Cas Number:
1219915-05-5
Molecular formula:
C11H11FO2
IUPAC Name:
(2S)-6-fluoro-2-(oxiran-2-yl)chromane
Test material form:
liquid
Details on test material:
Physical state: liquid
Appearence: light brown liquid
Specific details on test material used for the study:
- Batch n°: I16FB3013
- Analytical purity: 87.5%
- Expiration date: 07 June 2018
- Storage condition: at room temperature

Results and discussion

Flash point
Key result
Flash point:
132 °C
Atm. press.:
1 013.25 hPa
Remarks on result:
other: The flash-point is automatically corrected for atmospheric pressure by the flash point tester.

Any other information on results incl. tables

Preliminary test: The estimated flash-point of the test item was 132.5°C.

The results of the main study on the determination of the flash-point of the test item are given in the table below.

The difference between the results obtained with the two tests was ≤6°C. From this, it was concluded that the flash-point of the test item is the lowest flash-point obtained. 

 Test  Flash-point [°C]  Lowest flash-point [°C]
 1  134  132 
 2  132

Applicant's summary and conclusion

Interpretation of results:
GHS criteria not met
Conclusions:
The closed cup method was applied for the determination of the flash-point of JNJ-42819543-AAA (T001596).

The flash-point of the test item was 132°C.