Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Administrative data

First-aid measures

Description of first aid measures

. General information

.. Personal protection for the First Aider.

.. Take affected persons out of danger area and instruct to lie down.

.. Instantly remove any clothing soiled by the product.

. After inhalation

.. Supply fresh air.

.. In case of unconsciousness bring patient into stable side position for transport.

.. Seek medical treatment.

. After skin contact

.. Instantly wash with water and soap and rinse thoroughly.

.. Call a doctor immediately.

. After eye contact

.. Rinse opened eye for several minutes under running water.

..Seek medical treatment.

. After swallowing

.. Rinse out mouth and then drink plenty of water.

.. Do not induce vomiting; instantly call for medical help.

Most important symptoms and effects, both acute and delayed

..No further relevant information available.

. Information for doctor

.. Therapeutically measures: basic help, decontamination, symptomatic treatment.

Indication of any immediate medical attention and special treatment needed

.. No further relevant information available.

*

Fire-fighting measures

Extinguishing media

. Suitable extinguishing agents

.. CO2, extinguishing powder or water jet. Fight larger fire with foam.

. For safety reasons unsuitable extinguishing agents

.. Water with a full water jet.

Special hazards arising from the substance or mixture

.. Can be released in case of fire

.. Carbon monoxide (CO)

Advice for firefighters

. Protective equipment:

.. Do not inhale explosion gases or combustion gases.

.. Wear self-contained breathing apparatus.

. Additional information

.. Cool endangered containers with water spray jet.

*

Accidental release measures

Personal precautions, protective equipment and emergency procedures

.. Wear protective equipment. Keep unprotected persons away.

Environmental precautions:

.. Do not allow to enter drainage system, surface or ground water.

Methods and material for containment and cleaning up:

.. Ensure adequate ventilation.

.. Collect mechanically.

.. Send for recovery or disposal in suitable containers.

Reference to other sections

.. See Section   7 (Handling and storage) for information on safe handling

.. See Section   8 (Exposure controls/personal protection) for information on personal protection equipment.

.. See Section 13 (Disposal considerations) for information on disposal.

*

Handling and storage

Precautions for safe handling

.. Prevent formation of dust.

.. Open and handle container with care.

. Information about protection against explosions and fires:

.. Keep ignition sources away - Do not smoke.

.. Protect against electrostatic charges.

Conditions for safe storage, including any incompatibilities

. Storage

.. Requirements to be met by storerooms and containers:

... Storehouses and workplaces must be sufficiently ventilated.

.. Information about storage in one common storage facility:

... Store away from oxidising agents.

.. Further information about storage conditions:

... Keep container tightly sealed.

Specific end use(s)

. No further relevant information available.

*

Transport information

Shippingopen allclose all
SpecialProvisionsopen allclose all
Shippingopen allclose all
Remarksopen allclose all

Marine transport (UN RTDG/IMDG)

Shippingopen allclose all
Remarksopen allclose all
Shippingopen allclose all
Remarksopen allclose all
SpecialProvisionsopen allclose all

Exposure controls / personal protection

Exposure controls

. Personal protective equipment

. General protective and hygienic measures

.. The usual precautionary measures should be adhered to general rules for handling chemicals.

.. Take off immediately all contaminated clothing

.. Wash hands during breaks and at the end of the work.

.. Store protective clothing separately.

. Use skin protection cream for preventive skin protection.

.. Be sure to clean skin thoroughly after work and before breaks.

. Breathing equipment:

.. In case of brief exposure or low pollution use breathing filter apparatus . In case of intensive or longer exposure use breathing apparatus that is independent of circulating air.

.. Filter P3 (EN143)

. Protection of hands:

.. Only use chemical-protective gloves with CE-labelling of category III (EN 374).

. Material of gloves

.. Nitrile rubber

... Recommended thickness of the material: ≥ 0,425 mm

... Value for the permeation: > 480 min

.. Fluorocarbon rubber (Viton) / Butyl rubber

... Recommended thickness of the material: ≥ 0,7 mm

... Value for the permeation: > 480 min

.. The selection of the suitable gloves does not only depend on the material, but also on further marks of quality and varies from manufacturer to manufacturer.

. Penetration time of glove material

.. The exact break trough time has to be found out by the manufacturer of the protective gloves and has to be observed.

. For the permanent contact in work areas without heightened risk of injury (e.g. Laboratory) gloves made of the following material are suitable:

.. Nitrile rubber, NBR

.. Butyl rubber, BR

. Eye protection:

.. Gauze goggles

.. Tightly sealed safety glasses (EN 166)

. Body protection:

.. Protective work clothing (EN 340).

*

Stability and reactivity

Reactivity

. No further relevant information available.

Chemical stability

. Thermal decomposition / conditions to be avoided:

.. No decomposition if used according to specifications.

Possibility of hazardous reactions

. Risk of dust explosion

Conditions to avoid

. No further relevant information available.

Incompatible materials:

. No further relevant information available.

Hazardous decomposition products:

. No dangerous decomposition products known

*

Disposal considerations

Waste treatment methods

. Recommendation

.. Remove according to local authority recommendations, e.g. convey to a suitable incinerator.

. European waste catalogue

.. The disposal of waste within the EU is regulated by Directive 2008/98/EC

.. The waste code classification is to be carried out according to the European Waste Catalogue (EWC) specifically for each branch of industry and each type of process.

Uncleaned packagings:

. Recommendation:

.. Disposal must be made according to official regulations.

*