Registration Dossier

Diss Factsheets

Administrative data

Endpoint:
oxidising liquids
Cross-referenceopen allclose all
Reason / purpose for cross-reference:
reference to same study
Reference
Endpoint:
auto-ignition temperature (liquids)
Type of information:
experimental study
Adequacy of study:
key study
Reason / purpose for cross-reference:
reference to same study
Reason / purpose for cross-reference:
reference to same study
Reason / purpose for cross-reference:
reference to same study
Reason / purpose for cross-reference:
reference to same study
Qualifier:
according to guideline
Guideline:
EU Method A.15 (Auto-Ignition Temperature (Liquids and Gases))
Auto-ignition temperature:
ca. 336 °C
Atm. press.:
> 991 - < 992 hPa
Remarks on result:
preliminary test
Reason / purpose for cross-reference:
reference to same study
Reference
Endpoint:
explosive properties of explosives
Reason / purpose for cross-reference:
reference to same study
Reason / purpose for cross-reference:
reference to same study
Reason / purpose for cross-reference:
reference to same study
Reason / purpose for cross-reference:
reference to same study
Qualifier:
according to guideline
Guideline:
EU Method A.14 (Explosive properties)
Reason / purpose for cross-reference:
reference to same study
Reference
Endpoint:
flash point of flammable liquids
Type of information:
experimental study
Adequacy of study:
key study
Reason / purpose for cross-reference:
reference to same study
Reason / purpose for cross-reference:
reference to same study
Reason / purpose for cross-reference:
reference to same study
Reason / purpose for cross-reference:
reference to same study
Qualifier:
according to guideline
Guideline:
EU Method A.9 (Flash-Point)
Type of method:
equilibrium method closed cup
Flash point:
125 °C
Atm. press.:
1 013 hPa
Reason / purpose for cross-reference:
reference to same study
Reference
Endpoint:
vapour pressure
Type of information:
experimental study
Adequacy of study:
key study
Reason / purpose for cross-reference:
reference to same study
Reason / purpose for cross-reference:
reference to same study
Reason / purpose for cross-reference:
reference to same study
Reason / purpose for cross-reference:
reference to same study
Qualifier:
according to guideline
Guideline:
EU Method A.4 (Vapour Pressure)
Type of method:
effusion method: vapour pressure balance
Temp.:
25 °C
Vapour pressure:
0.028 Pa

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
2007
Report date:
2007

Materials and methods

Test guideline
Qualifier:
according to guideline
Guideline:
EU Method A.21 (Oxidising Properties (Liquids))

Test material

Constituent 1
Test material form:
liquid

Results and discussion

Applicant's summary and conclusion