Registration Dossier

Diss Factsheets

Physical & Chemical properties

Flash point

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
flash point of flammable liquids
Type of information:
experimental study
Adequacy of study:
key study
Study period:
Febr. 19, - March 14, 2019
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study
Qualifier:
according to guideline
Guideline:
EU Method A.9 (Flash-Point)
GLP compliance:
no
Type of method:
closed cup
Flash point apparatus:
Pensky-Martens apparatus
Key result
Flash point:
200 °C
Atm. press.:
101 325 Pa

Findings

Program

Flash point
inoC

Mean
inoC

Notes

Search

200.8

 

not used for calculation (pre-test)

ENISO2719-A

201.0

200,0

difference < 2 K

ENISO2719-A

199.0

 

The flash point is given as the mean value of the duplicate determination. The measured flash point is therefore 200.0 ± 1.0°C (corresponding to 473.2 ± 1.0 K).

Interpretation of results:
GHS criteria not met
Conclusions:
The measured flash point of Ethylphthalyl ethyl glycolate is 200.0 ± 1.0 °C at 101 325 Pa.

Description of key information

The measured flash point of Ethylphthalyl ethyl glycolate is 200.0 ± 1.0 °C.

Key value for chemical safety assessment

Flash point at 101 325 Pa:
200 °C

Additional information