Registration Dossier
Registration Dossier
Diss Factsheets
Use of this information is subject to copyright laws and may require the permission of the owner of the information, as described in the ECHA Legal Notice.
EC number: 835-273-2 | CAS number: 852056-62-3
- Life Cycle description
- Uses advised against
- Endpoint summary
- Appearance / physical state / colour
- Melting point / freezing point
- Boiling point
- Density
- Particle size distribution (Granulometry)
- Vapour pressure
- Partition coefficient
- Water solubility
- Solubility in organic solvents / fat solubility
- Surface tension
- Flash point
- Auto flammability
- Flammability
- Explosiveness
- Oxidising properties
- Oxidation reduction potential
- Stability in organic solvents and identity of relevant degradation products
- Storage stability and reactivity towards container material
- Stability: thermal, sunlight, metals
- pH
- Dissociation constant
- Viscosity
- Additional physico-chemical information
- Additional physico-chemical properties of nanomaterials
- Nanomaterial agglomeration / aggregation
- Nanomaterial crystalline phase
- Nanomaterial crystallite and grain size
- Nanomaterial aspect ratio / shape
- Nanomaterial specific surface area
- Nanomaterial Zeta potential
- Nanomaterial surface chemistry
- Nanomaterial dustiness
- Nanomaterial porosity
- Nanomaterial pour density
- Nanomaterial photocatalytic activity
- Nanomaterial radical formation potential
- Nanomaterial catalytic activity
- Endpoint summary
- Stability
- Biodegradation
- Bioaccumulation
- Transport and distribution
- Environmental data
- Additional information on environmental fate and behaviour
- Ecotoxicological Summary
- Aquatic toxicity
- Endpoint summary
- Short-term toxicity to fish
- Long-term toxicity to fish
- Short-term toxicity to aquatic invertebrates
- Long-term toxicity to aquatic invertebrates
- Toxicity to aquatic algae and cyanobacteria
- Toxicity to aquatic plants other than algae
- Toxicity to microorganisms
- Endocrine disrupter testing in aquatic vertebrates – in vivo
- Toxicity to other aquatic organisms
- Sediment toxicity
- Terrestrial toxicity
- Biological effects monitoring
- Biotransformation and kinetics
- Additional ecotoxological information
- Toxicological Summary
- Toxicokinetics, metabolism and distribution
- Acute Toxicity
- Irritation / corrosion
- Sensitisation
- Repeated dose toxicity
- Genetic toxicity
- Carcinogenicity
- Toxicity to reproduction
- Specific investigations
- Exposure related observations in humans
- Toxic effects on livestock and pets
- Additional toxicological data

Endpoint summary
Administrative data
Description of key information
For the assessment of irritation / corrosion in vitro methods have been applied. The following results have been obtained:
OECD 431: not corrosive to skin
OECD 439: not irritating to skin
OECD 492: not irritating to eye
Key value for chemical safety assessment
Skin irritation / corrosion
Link to relevant study records
- Endpoint:
- skin corrosion: in vitro / ex vivo
- Type of information:
- experimental study
- Adequacy of study:
- weight of evidence
- Study period:
- Oct 04, 2017 - Jan 09, 2018
- Reliability:
- 1 (reliable without restriction)
- Rationale for reliability incl. deficiencies:
- guideline study
- Qualifier:
- according to guideline
- Guideline:
- other: Council Regulation (EC) No. 440/2008 laying down test methods pursuant to Regulation (EC) No. 1907/2006. B.40.bis. In vitro skin corrosion: human skin model test
- Deviations:
- no
- Qualifier:
- according to guideline
- Guideline:
- OECD Guideline 431 (In Vitro Skin Corrosion: Reconstructed Human Epidermis (RHE) Test Method)
- Version / remarks:
- July 29, 2016
- Deviations:
- no
- Qualifier:
- according to guideline
- Guideline:
- other: INVITTOX Protocol SkinEthic Skin Corrosivity Test, April 2012.
- Deviations:
- no
- GLP compliance:
- yes (incl. QA statement)
- Test system:
- human skin model
- Source species:
- human
- Cell type:
- non-transformed keratinocytes
- Cell source:
- foreskin from a single donor
- Justification for test system used:
- standard model
- Vehicle:
- unchanged (no vehicle)
- Remarks:
- No vehicle used in this study; The test item was applied neat to the tissues.
- Details on test system:
- CELL CULTURE
- Supplier: EpiSkin/SkinEthic Laboratories, Lyon, France)
- Source: human keratinocytes cultured on a polycarbonate filter in conditions which permit their terminal differentiation
- Format: 24 well plate
- Batch: 17-RHE-118
- Expires: Nov 27, 2017
TEMPERATURE USED FOR TEST SYSTEM
- Temperature used during treatment: room temperature
- Temperature of post-treatment incubation: 37°C
REMOVAL OF THE TEST MATERIAL AND CONTROL
At the end of the exposure periods, the test item, positive and negative control was removed immediately by gently rinsing with a minimum volume of 20 mL DPBS using a pipette. Excess DPBS was removed by gently shaking the tissue inserts and blotting the bottom of the tissue inserts with blotting paper. - Control samples:
- yes, concurrent negative control
- Amount/concentration applied:
- TEST MATERIAL
- Amount(s) applied (volume or weight with unit): 20 mg ± 3 mg of solid test material
- Concentration (if solution): n/a
VEHICLE
- Amount(s) applied (volume or weight with unit): n/a
- Concentration (if solution): n/a
- Lot/batch no. (if required): n/a
- Purity: n/a
NEGATIVE CONTROL
- Amount(s) applied (volume or weight): 40 µL ± 3 µl (deionised water )
- Concentration (if solution): n/a
POSITIVE CONTROL
- Amount(s) applied (volume or weight): 40 µL ± 3 µl
- Concentration (if solution): An 8N potassium hydroxide solution dissolved deionised water pure was used as positive control. - Duration of treatment / exposure:
- 3 min & 1 hour
- Number of replicates:
- 2
- Irritation / corrosion parameter:
- % tissue viability
- Run / experiment:
- Experiment 1 / Run 1 (3 min)
- Value:
- 94.3
- Vehicle controls validity:
- not applicable
- Remarks:
- The test item was applied neat to the tissues
- Negative controls validity:
- valid
- Positive controls validity:
- valid
- Remarks on result:
- other: Non-corrosive
- Irritation / corrosion parameter:
- % tissue viability
- Run / experiment:
- Experiment 1 / Run 1 (1 hour)
- Value:
- 97.2
- Vehicle controls validity:
- not applicable
- Remarks:
- The test item was applied neat to the tissues
- Negative controls validity:
- valid
- Positive controls validity:
- valid
- Remarks on result:
- other: Non-corrosive
- Other effects / acceptance of results:
- OTHER EFFECTS:
- Visible damage on test system: none
- Direct-MTT reduction: none
- Colour interference with MTT: none
ACCEPTANCE OF RESULTS:
Acceptability of the Quality Control Data of the Skin Model with Reference to Historical Batch Data:
Acceptance Criterion Result
Negative control OD ≥ 0.8 and ≤ 3.0 1.826 to 1.879
Acceptability of the Positive and Negative Control stated by Episkin/SkinEthic Laboratories:
Acceptance Criterion Result
Mean OD negative control ≥ 0.8 and ≤ 3.0 1.879 (3 min)
1.826 (1 hour)
Mean viability positive control < 15% after 1-hour exposure 0.5%
Range between identically treated < 30% 14.4% (3 min)
tissues with test item 18.3% (1 hour)
Acceptability of the Positive and Negative Control based on Historical Data of the Testing Laboratory:
Acceptance Criterion Result
Mean OD negative control ≥ 1.568 (3 min) 1.902 (3 min)
≥ 1.434 (1 hour) 1.973 (1 hour)
Mean viability positive control ≤ 0.95% 0.58%
Negative Control, Positive Control and Test Substance Data Acceptance Criteria stated by the Testing Laboratory:
Group Acceptance Criterion Result
Range between identically Negative control < 30% 2.6% (3 min)
treated tissues 8.2% (1 hour)
Positive control < 30% 16.7% (1 hour)
Test substance < 30% 8.4% (3 min)
0.7% (1 hour)
The study met all acceptance criteria. - Interpretation of results:
- GHS criteria not met
- Remarks:
- Non-corrosive
- Conclusions:
- This study was performed according to GLP and the methods applied are fully compliant with OECD TG 431. Under the conditions of the present study, the test item is not considered to possess a corrosive potential to skin.
- Executive summary:
Objective
The objective of the present study was to investigate the potential of the test item to induce skin corrosion in anin vitrohuman skin model.
Study Design
The test item was applied topically to a human reconstructed skin model followed by determination of the cell viability. Cell viability was determined by enzymatic conversion of vital dye MTT into a blue formazan salt and measurement of the formazan salt after extraction from tissues. The percent reduction of cell viability in comparison to untreated negative controls was used to predict the skin corrosion potential.
Duplicates of the human skin RHE-model were treated with the test item or the negative control for 3 minutes and additional 1 hour. Duplicates with the positive control were only treated for
1 hour. 40 ± 3 µL of either the negative control (deionised water) or the positive control (potassium hydroxide, 8N) were applied to the tissues. Before application of 20 ± 3 mg of the solid test item, 20 ± 2 µL of deionised water was spread to the epidermis surface to improve the contact between the test item and the epidermis.Results
After treatment with the positive control (potassium hydroxide, 8N) the mean viability value was 0.7% and, thus, lower than the historically established threshold of 0.95%. After treatment with the negative control (deionised water) the mean ODs were 1.879 (3 minutes exposure) and 1.826 (1 hour exposure) and, thus, higher than the historically established thresholds of 1.568 and 1.434, respectively. Thus, the acceptance criteria were met.
Following treatment with the test item, the tissue viability was ≥50% after 3 minutes exposure (mean viability: 94.3%) and ≥15% after 1 hour exposure (mean viability: 97.2%),i.e.according to OECD 431 the test item is not considered as corrosive to skin.
Conclusion
Under the conditions of the present study, the test item is not considered to possess a corrosive potential to skin.
- Endpoint:
- skin irritation: in vitro / ex vivo
- Type of information:
- experimental study
- Adequacy of study:
- weight of evidence
- Study period:
- 17 Apr 2019 - Jun 2019
- Reliability:
- 1 (reliable without restriction)
- Rationale for reliability incl. deficiencies:
- guideline study
- Qualifier:
- according to guideline
- Guideline:
- EU Method B.46 (In Vitro Skin Irritation: Reconstructed Human Epidermis Model Test)
- Version / remarks:
- Commission Regulation (EU) No. 640/2012 amending, for the purpose of its adaption to technical progress, Regulations (EC) No. 440/2008 laying down test methods pursuant to Regulation (EC) No. 1907/2006 of the European Parliament and the council on the Registration, Evaluation, Authorisation and Restriction of Chemicals (REACH).
- Deviations:
- no
- Qualifier:
- according to guideline
- Guideline:
- OECD Guideline 439 (In Vitro Skin Irritation: Reconstructed Human Epidermis Test Method)
- Version / remarks:
- July 28, 2015
- Deviations:
- no
- Qualifier:
- according to guideline
- Guideline:
- other: Skinethic skin irritation test -42bis Standard operating procedure (SOP) 2009
- Deviations:
- no
- GLP compliance:
- yes (incl. QA statement)
- Specific details on test material used for the study:
- TREATMENT OF TEST MATERIAL PRIOR TO TESTING
No pre-treatment; The test item was applied neat to the tissues. - Test system:
- human skin model
- Source species:
- human
- Cell type:
- non-transformed keratinocytes
- Cell source:
- foreskin from a single donor
- Justification for test system used:
- standard model
- Vehicle:
- unchanged (no vehicle)
- Remarks:
- No vehicle used in this study; The test item was applied neat to the tissues.
- Details on test system:
- CELL CULTURE
- Supplier: EpiSkin/SkinEthic Laboratories, Lyon, France)
- Source: human keratinocytes cultured on a polycarbonate filter in conditions which permit their terminal differentiation
- Format: 24 well plate
- Batch: 19-RHE-087
- Expires: May 27, 2019
TEMPERATURE USED FOR TEST SYSTEM
- Temperature used during treatment: room temperature
- Temperature of post-treatment incubation: 37°C
REMOVAL OF THE TEST MATERIAL AND CONTROL
After the end of the treatment interval, the residual test item was removed immediately by gently rinsing with a minimum volume of 25 mL DPBS using a pipette. Excess DPBS was removed by gently shaking the inserts and blotting the bottom with blotting paper.
DYE BINDING METHOD
- Dye used in the dye-binding assay: MTT
- Spectrophotometer:ELx800, BioTek Instruments GmbH, Bad Friedrichshall, Germany at 570 nm - Control samples:
- yes, concurrent negative control
- Amount/concentration applied:
- TEST MATERIAL: 16 mg ± 2 mg
NEGATIVE CONTROL: 16 µL (Dulbecco`s Phosphate-Buffered Saline)
POSITIVE CONTROL: 16 µL (5% aqueous solution of sodium dodecyl sulfate in deionised water) - Duration of treatment / exposure:
- 42 min (± 1 minute)
- Duration of post-treatment incubation (if applicable):
- 42 hours (± 1 hour)
- Number of replicates:
- 3
- Irritation / corrosion parameter:
- % tissue viability
- Run / experiment:
- Experiment 1 / Run 1
- Value:
- 92.5
- Vehicle controls validity:
- not applicable
- Remarks:
- The test item was applied neat to the tissues
- Negative controls validity:
- valid
- Positive controls validity:
- valid
- Remarks on result:
- no indication of irritation
- Other effects / acceptance of results:
- OTHER EFFECTS:
- Visible damage on test system: none
- Direct-MTT reduction: none
- Colour interference with MTT: none
ACCEPTANCE OF RESULTS:
Acceptability of the Quality Control Data of the Skin Model with Reference to Historical Batch Data:
Acceptance Criterion Result
Negative control OD ≥ 0.8 and ≤ 3.0 1.663 to 2.041
Acceptability of the Positive and Negative Control stated by Episkin/SkinEthic Laboratories:
Acceptance Criterion Result
Mean OD negative control ≥ 1.2 1.810
Mean viability positive control < 40% 1.3%
SD of group-mean value ≤ 18% 7.7% (positive control)
11.2% (negative control)
Acceptability of the Positive and Negative Control based on Historical Data of the Testing Laboratory:
Acceptance Criterion Result
Mean OD negative control ≥ 1.423 1.810
Mean viability positive control ≤ 2.80% 1.3%
Test Item Data Acceptance Criteria:
Acceptance Criterion Result
SD of group-mean value ≤ 18% 7.2%
The study met all acceptance criteria. - Interpretation of results:
- GHS criteria not met
- Conclusions:
- This study was performed according to GLP and the methods applied are fully compliant with OECD TG 439. Under the conditions of the present study, the test item is not considered to possess an irritant potential to skin (UN GHS: No Category).
- Executive summary:
Objective
The objective of the present study was to investigate the potential of the test item to induce skin irritation in anin vitrohuman skin model.
Study Design
The test item was applied topically to a human reconstructed skin model followed by determination of the cell viability. Cell viability was determined by enzymatic conversion of vital dye MTT into a blue formazan salt and measurement of the formazan salt after extraction from tissues. The percent reduction of cell viability in comparison to untreated negative controls was used to predict the skin irritation potential.
Triplicates of the human skin RHE-model were treated with the test item, the negative or the positive control for 42 minutes (± 1 minute). 16 µL of either the negative control (DPBS-buffer) or the positive control (5% aqueous solution of sodium dodecyl sulfate) were applied to the tissues. Before application of 16 mg of the solid test item, 10 µL of deionised water was spread to the epidermis surface to improve the contact between the test item and the epidermis.
Results
All acceptability criteria after treatment with the negative control (DPBS-buffer) and the positive control (5% aqueous solution of sodium dodecyl sulfate) were met.
Following treatment with the test item, the tissue viability was 95.5% and, thus, higher than 50%,i.e.according to OECD 439 the test item is considered as non-irritant to skin (UN GHS: No Category).
Conclusion
Under the conditions of the present study, the test item is not considered to possess an irritant potential to skin (UN GHS: No Category).
Referenceopen allclose all
Group | Time / [min] | Mean OD | Mean Relative viability / [%] |
Negative Control | 3 | 1.879 | 100.0 |
Negative Control | 60 | 1.826 |
100.0 |
Positive Control |
60 |
0.010 |
0.5 |
Test Material | 3 | 1.772 | 94.3 |
Test Material | 60 | 1.775 | 97.2 |
Group | Time / [min] | Mean OD | Mean Relative viability / [%] |
Negative Control | 42 | 1.810 | 100 |
Positive Control | 42 | 0.024 |
1.3 |
Test Material |
42 |
1.674 |
92.5 |
Endpoint conclusion
- Endpoint conclusion:
- no adverse effect observed (not irritating)
Eye irritation
Link to relevant study records
- Endpoint:
- eye irritation: in vitro / ex vivo
- Type of information:
- experimental study
- Adequacy of study:
- key study
- Study period:
- Aug 10, 2018 - Sep 24, 2018
- Reliability:
- 1 (reliable without restriction)
- Rationale for reliability incl. deficiencies:
- guideline study
- Qualifier:
- according to guideline
- Guideline:
- OECD Guideline 492 (Reconstructed Human Cornea-like Epithelium (RhCE) Test Method for Identifying Chemicals Not Requiring Classification and Labelling for Eye Irritation or Serious Eye Damage)
- Version / remarks:
- October 9, 2017
- Deviations:
- no
- Qualifier:
- according to guideline
- Guideline:
- other: EpiOcular Eye Irritation Test (OCL-200-EIT) for the prediction of acute ocular irritation of chemicals; For use with MatTek Corporation`s Reconstructed Human EpiOcular Model; MatTek Corporation
- Version / remarks:
- June 29, 2015
- Deviations:
- no
- GLP compliance:
- yes (incl. QA statement)
- Vehicle:
- unchanged (no vehicle)
- Controls:
- yes, concurrent positive control
- yes, concurrent negative control
- Amount / concentration applied:
- TEST MATERIAL: 50 µL per tissue
NEGATIVE / VEHICLE CONTROL: 50 µL per tissue
Sterile deionized water was used as negative control.
POSITIVE CONTROL: 50 µL per tissue
Designation: Art. 8.09711
Synonym: Methyl acetate
Supplier: Merck KGaA
CAS No.: 79-20-9
Batch No.: S7451611
Appearance: Liquid
Content (GC): 99.6 % (a/a)
Expiry Date: June 30, 2022
Storage conditions: Tightly closed, dark, at room temperature (15 – 25°C) - Duration of treatment / exposure:
- 30 ± 2 minutes
- Number of animals or in vitro replicates:
- in vitro: duplicate design
- Irritation parameter:
- other: Viability %
- Run / experiment:
- Run 1 / Experiment 1
- Value:
- 100.7
- Vehicle controls validity:
- not examined
- Negative controls validity:
- valid
- Positive controls validity:
- valid
- Remarks on result:
- no indication of irritation
- Other effects / acceptance of results:
- OTHER EFFECTS:
- Visible damage on test system: No observations
ACCEPTANCE OF RESULTS:
The results are acceptable if:
1. The negative control OD >0.8 and <2.5
2. The mean relative viability of the positive control is:
a) 30 minute exposure: below 50% of control viability
b) 6 hour exposure: below 50% of control viability
3. The difference of viability between the two relating tissues of a single chemical is <20% in the same run (for positive and negative control tissues and tissues of single chemicals). This applies also to the killed controls (single chemicals and negative killed control) and the colorant controls which are calculated as percent values related to the viability of the relating negative control. - Interpretation of results:
- GHS criteria not met
- Conclusions:
- Under the conditions of the present study, the test item did not show an eye hazard potential. The test item is identified as not requiring classification and labeling according to UN GHS (No Category).
- Executive summary:
Objective
The objective of the present study was to investigate the potential of the test item to induce eye irritation in anin vitrohuman cornea model.
Study Design
The test item was applied topically to a reconstructed human cornea-like epithelium model (EpiOcular) followed by determination of the cell viability. Cell viability was determined by enzymatic conversion of vital dye MTT into a blue formazan salt and measurement of the formazan salt after extraction from tissues. The percent reduction of cell viability in comparison to untreated negative controls was used to predict the eye irritation potential.
Duplicates of the EpiOcular-model were treated with the test item, the negative or the positive control for 6 hours (± 15 minutes). 50 mg of the test item and 50 µL of either the negative control (sterile deionized water) or the positive control (methyl acetate) were applied to the tissues.
Results
After treatment with the negative control (sterile deionized water) the mean OD was 1.888 (study acceptance criterion: >0.8 and <2.5). Treatment with the positive control (methyl acetate) revealed a mean viability value of 17.6% (study acceptance criterion: <50%). Thus, the acceptance criteria were met.
Following treatment with the test item the test material, the tissue viability was 100.7% and, thus, higher than 60%, i.e. according to OECD 492 the test item is identified as not requiring classification and labeling according to UN GHS (No Category).
Conclusion
Under the conditions of the present study, the test item did not show an eye hazard potential. The test item is identified as not requiring classification and labeling according to UN GHS (No Category).
Reference
Mean OD | Mean Viability | |
Negative Control | 1.874 | 100.0% |
Positive Control | 0.330 | 17.6% |
Test Item | 1.888 | 100.7% |
Endpoint conclusion
- Endpoint conclusion:
- no adverse effect observed (not irritating)
Respiratory irritation
Endpoint conclusion
- Endpoint conclusion:
- no study available
Additional information
Justification for classification or non-classification
Based on the provided information the test item is not classified for skin and eye irritation/corrosion according to the EU Regulation (EC) No 1272/2008 on Classification, Labelling and Packaging of Substances and Mixtures.
Information on Registered Substances comes from registration dossiers which have been assigned a registration number. The assignment of a registration number does however not guarantee that the information in the dossier is correct or that the dossier is compliant with Regulation (EC) No 1907/2006 (the REACH Regulation). This information has not been reviewed or verified by the Agency or any other authority. The content is subject to change without prior notice.