Registration Dossier
Registration Dossier
Data platform availability banner - registered substances factsheets
Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.
The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.
Diss Factsheets
Use of this information is subject to copyright laws and may require the permission of the owner of the information, as described in the ECHA Legal Notice.
EC number: 203-601-8 | CAS number: 108-63-4
- Life Cycle description
- Uses advised against
- Endpoint summary
- Appearance / physical state / colour
- Melting point / freezing point
- Boiling point
- Density
- Particle size distribution (Granulometry)
- Vapour pressure
- Partition coefficient
- Water solubility
- Solubility in organic solvents / fat solubility
- Surface tension
- Flash point
- Auto flammability
- Flammability
- Explosiveness
- Oxidising properties
- Oxidation reduction potential
- Stability in organic solvents and identity of relevant degradation products
- Storage stability and reactivity towards container material
- Stability: thermal, sunlight, metals
- pH
- Dissociation constant
- Viscosity
- Additional physico-chemical information
- Additional physico-chemical properties of nanomaterials
- Nanomaterial agglomeration / aggregation
- Nanomaterial crystalline phase
- Nanomaterial crystallite and grain size
- Nanomaterial aspect ratio / shape
- Nanomaterial specific surface area
- Nanomaterial Zeta potential
- Nanomaterial surface chemistry
- Nanomaterial dustiness
- Nanomaterial porosity
- Nanomaterial pour density
- Nanomaterial photocatalytic activity
- Nanomaterial radical formation potential
- Nanomaterial catalytic activity
- Endpoint summary
- Stability
- Biodegradation
- Bioaccumulation
- Transport and distribution
- Environmental data
- Additional information on environmental fate and behaviour
- Ecotoxicological Summary
- Aquatic toxicity
- Endpoint summary
- Short-term toxicity to fish
- Long-term toxicity to fish
- Short-term toxicity to aquatic invertebrates
- Long-term toxicity to aquatic invertebrates
- Toxicity to aquatic algae and cyanobacteria
- Toxicity to aquatic plants other than algae
- Toxicity to microorganisms
- Endocrine disrupter testing in aquatic vertebrates – in vivo
- Toxicity to other aquatic organisms
- Sediment toxicity
- Terrestrial toxicity
- Biological effects monitoring
- Biotransformation and kinetics
- Additional ecotoxological information
- Toxicological Summary
- Toxicokinetics, metabolism and distribution
- Acute Toxicity
- Irritation / corrosion
- Sensitisation
- Repeated dose toxicity
- Genetic toxicity
- Carcinogenicity
- Toxicity to reproduction
- Specific investigations
- Exposure related observations in humans
- Toxic effects on livestock and pets
- Additional toxicological data
Acute Toxicity: inhalation
Administrative data
- Endpoint:
- acute toxicity: inhalation
- Type of information:
- experimental study
- Adequacy of study:
- key study
- Study period:
- 29 Feb 1998 - 11 Mar 1998
- Reliability:
- 1 (reliable without restriction)
- Rationale for reliability incl. deficiencies:
- guideline study
Data source
Reference
- Reference Type:
- study report
- Title:
- Unnamed
- Year:
- 1 998
- Report date:
- 1998
Materials and methods
Test guidelineopen allclose all
- Qualifier:
- according to guideline
- Guideline:
- OECD Guideline 403 (Acute Inhalation Toxicity)
- Version / remarks:
- (1981)
- Deviations:
- no
- Qualifier:
- according to guideline
- Guideline:
- EU Method B.2 (Acute Toxicity (Inhalation))
- Version / remarks:
- (1992)
- Deviations:
- no
- Qualifier:
- according to guideline
- Guideline:
- EPA OPP 81-3 (Acute inhalation toxicity)
- Version / remarks:
- (1984)
- Deviations:
- no
- Qualifier:
- according to guideline
- Guideline:
- EPA OTS 798.1150 (Acute inhalation toxicity)
- Version / remarks:
- (1992)
- Deviations:
- no
- GLP compliance:
- yes
- Test type:
- standard acute method
- Limit test:
- yes
Test material
- Reference substance name:
- Bis(2-ethylhexyl) adipate
- EC Number:
- 203-090-1
- EC Name:
- Bis(2-ethylhexyl) adipate
- Cas Number:
- 103-23-1
- Molecular formula:
- C22H42O4
- IUPAC Name:
- bis(2-ethylhexyl) adipate
- Details on test material:
- - Name of test material (as cited in study report): [trade name]
- Substance No.: 97/492-1
- Date of production: 07 Nov 1997
- Physical state: colourless, clear liquid
- Analytical purity: 99.7% (according to analytical report 97L00845)
- Lot/batch No.: # 22513
- Stability: The stability of the test substance over the study period has been proven by reanalysis (analytical report 98L00166)
- Homogeneity: homogeneous (analytical report 97L00845 )
- Storage condition of test material: at room temperature
Constituent 1
Test animals
- Species:
- rat
- Strain:
- other: SPF Wistar/Chbb:THOM
- Sex:
- male/female
- Details on test animals or test system and environmental conditions:
- TEST ANIMALS
- Source: Dr. K. Thomae GmbH, Biberach, Germany
- Age at study initiation: approximately 8-9 weeks
- Weight at study initiation: 284±9.5 g
- Housing: individually in cages type DK III (Becker, Germany) without bedding
- Diet: KLIBA rat/mouse/hamster laboratory diet 10 mm pellets (Klingentalmühle AG, Kaiseraugst, Switzerland), ad libitum during the post-exposure observation period
- Water: ad libitum during the post-exposure observation period
- Acclimation period: at least 1 week
ENVIRONMENTAL CONDITIONS
- Temperature (°C): 20-24
- Humidity (%): 30-70
- Photoperiod (hrs dark / hrs light): 12/12
Administration / exposure
- Route of administration:
- inhalation: aerosol
- Type of inhalation exposure:
- nose/head only
- Vehicle:
- air
- Mass median aerodynamic diameter (MMAD):
- 1.4 µm
- Geometric standard deviation (GSD):
- 3
- Details on inhalation exposure:
- GENERATION OF TEST ATMOSPHERE / CHAMBER DESCRIPTION
- Exposure apparatus: Head-nose inhalation system INA 20 (glass-steel construction)
- Exposure chamber volume: approximately 55 L
- Method of holding animals in test chamber: the animals were restrained in tubes and their snouts projected into the inhalation chamber
- Source and rate of air: compressed air; supply air flow : 1500L/h, exhaust air flow: 1350 L/h
- Method of conditioning air: not specified (temperature and humidity were measured in 30 min-intervals). No surveillance of the oxygen content in the inhalation system was performed. The air change was judged to be sufficient to prevent oxygen depletion by the breathing of the animals and the concentration of the test substance used could not have a substantial influence on oxygen partial pressure .
- System of generating aerosol: Amounts of the test substance were supplied to the two-component atomizer by means of the piston metering pump. By means of compressed air, the aerosol was produced inside the aerosol mixing vessel and was passed through the cyclonic separator into the exposure system. The flow rate of the test substance preparation to the atomizer was 35.0 mL/h .
- Method of particle size determination: The following equipment was used for the particle size determination: Stack Sampler Mark III (Andersen), Vacuum Compressed Air Pump (Millipore), Sampling probe (internal diameter 6.9 mm), Limiting orifice 3 L/min, Balance: Sartorius M3P and Sartorius LC 1201S. Before sampling, the impactor was assembled with preweighed glass-fiber collecting discs, and a backup particle filter. The impactor was connected to the vacuum pump and one sample was taken from the breathing zone of the animals not earlier than 30 minutes after the beginning of the exposure. The sample volume was 9 L. After sampling the impactor was taken apart and the collecting discs and the backup particle filter were re-weighed. The amounts of material adsorbed to the walls of the impactor and in the sampling probe (wall losses) were also determined quantitatively.
- Temperature, humidity, pressure in air chamber: 21.5 °C, 2.1% rel. humidity
TEST ATMOSPHERE
- Brief description of analytical method used: Gravimetric determination of the inhalation atmosphere concentration.
- Samples taken from breathing zone: yes (immediately adjacent to the animals' noses)
TEST ATMOSPHERE (if not tabulated)
- Particle size distribution: please refer to table 1
- MMAD (Mass median aerodynamic diameter) / GSD (Geometric st. dev.): 1.4 µm/3.0 - Analytical verification of test atmosphere concentrations:
- yes
- Remarks:
- gravimetric
- Duration of exposure:
- 4 h
- Concentrations:
- 5.7 mg/L
- No. of animals per sex per dose:
- 5
- Control animals:
- no
- Details on study design:
- - Duration of observation period following administration: 14 days
- Frequency of observations: A check for overt clinical signs of toxicity or mortality as well as a check for the presence of feed and drinking water was made twice a day on workdays and once daily on weekends and public holidays. Detailed clinical observations were recorded for each animal separately several times during exposure and at least once on each workday in the observation period.
- Frequency of weighing: prior to exposure, after 7 days and after 14 days
- Necropsy of survivors performed: yes
- Other examinations performed: clinical signs, body weight - Statistics:
- A Probit analysis was performed.
Results and discussion
Effect levels
- Key result
- Sex:
- male/female
- Dose descriptor:
- LC50
- Effect level:
- > 5.7 mg/L air (analytical)
- Based on:
- test mat.
- Exp. duration:
- 4 h
- Mortality:
- No mortality occurred throughout the study period.
- Clinical signs:
- other: Clinical examination revealed irregular and accelerated respiration as well as attempts to escape and piloerection. No clinical signs could be detected from post dosing day 5 onward.
- Body weight:
- All animals of this study gained body weight as expected.
- Gross pathology:
- No gross pathological abnormalities were detected in the animals at study termination.
Applicant's summary and conclusion
- Interpretation of results:
- other: CLP/EU GHS criteria not met, no classification required according to Regulation (EC) No. 1272/2008
Information on Registered Substances comes from registration dossiers which have been assigned a registration number. The assignment of a registration number does however not guarantee that the information in the dossier is correct or that the dossier is compliant with Regulation (EC) No 1907/2006 (the REACH Regulation). This information has not been reviewed or verified by the Agency or any other authority. The content is subject to change without prior notice.