Registration Dossier

Diss Factsheets

Administrative data

Endpoint:
vapour pressure
Type of information:
experimental study
Adequacy of study:
key study
Study period:
2020
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
2020
Report date:
2020

Materials and methods

Test guideline
Qualifier:
according to guideline
Guideline:
other: DIN EN 13016
Version / remarks:
Triple Expansion Method
Deviations:
no
GLP compliance:
no
Other quality assurance:
other: ISO 9001:2015
Type of method:
static method

Test material

Reference
Name:
Unnamed
Type:
Constituent
Test material form:
liquid
Specific details on test material used for the study:
Test guideline: DIN EN 13016
Method: Triple Expansion Method
Apparatus: Minivap VP/VPL-Vision, Grabner Instruments

Results and discussion

Vapour pressureopen allclose all
Key result
Temp.:
20 °C
Vapour pressure:
12.9 hPa
Key result
Temp.:
50 °C
Vapour pressure:
40.5 hPa

Applicant's summary and conclusion

Conclusions:
Vapor Pressure
DIN EN 13016
Triple Expansion Method
12.9 hPa @ 20°C
40.5 hPa @ 50°C