Particle size data was acquired in accordance with OECD Guideline 110. The results are as follows:

Proportion of test item having an inhalable particle size <100µm: 32.7%

Proportion of test item having a thoracic particle size <10.0µm: 10.8%

Proportion of test item having a respirable particle size <5.5µm: 2.02%

Too few particles were of a size less than 10.0 µm to allow accurate assessment of the mass median aerodynamic diameter, OECD 110, Fox & White, 2011.