Registration Dossier

Diss Factsheets

Physical & Chemical properties

Viscosity

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
viscosity
Type of information:
experimental study
Adequacy of study:
key study
Study period:
Last updated 2016 May 23
Reliability:
2 (reliable with restrictions)
Rationale for reliability incl. deficiencies:
test procedure in accordance with national standard methods with acceptable restrictions
Justification for type of information:
Specification data long held by the manufacturer. Practical handling experience has not resulted in the questioning of the accuracy of this data.
Qualifier:
equivalent or similar to guideline
Guideline:
OECD Test Guideline 114 (Viscosity of Liquids)
Principles of method if other than guideline:
The viscosity of a liquid is measured in a rotational viscometer.
GLP compliance:
no
Type of method:
rotational viscometer (dynamic)
Standard covering the apparatus used:
no information
Key result
Temp.:
other: 25 ˚C
Parameter:
dynamic viscosity (in mPa s)
Value:
ca. 1 500
Conclusions:
The test substance was observed to have a viscosity of 1500 cP at 25 ˚C.

Description of key information

1500 cPs

Key value for chemical safety assessment

Viscosity:
1 500 mPa · s (dynamic)
at the temperature of:
25 °C

Additional information

The test substance was observed to have a viscosity of 1500 cPs (mPa s) at 25 ˚C.