Registration Dossier

Diss Factsheets

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
flammable solids
Type of information:
experimental study
Adequacy of study:
key study
Study period:
19/05/2015
Reliability:
2 (reliable with restrictions)
Rationale for reliability incl. deficiencies:
test procedure in accordance with national standard methods
Qualifier:
according to guideline
Guideline:
EU Method A.10 (Flammability (Solids))
GLP compliance:
yes
Test procedure:
burning rate test: preliminary screening test
Moisture (wt %):
0.38
Remarks on result:
other: The sample melted on contact with the ignition source and ignited with a small yellow flame, which extinguished immediately after removal of the ignition source
Interpretation of results:
not classified based on GHS criteria
Executive summary:

The substance is not highly flammable

Description of key information

Key value for chemical safety assessment

Flammability:
not classified

Additional information

Justification for classification or non-classification