Registration Dossier

Diss Factsheets

Administrative data

Endpoint:
flash point of flammable liquids
Type of information:
experimental study
Adequacy of study:
key study
Study period:
2018
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
2018
Report date:
2018

Materials and methods

Test guideline
Qualifier:
according to guideline
Guideline:
ISO 2719 (Determination of flash point - Pensky-Martens closed cup method)
Deviations:
no
GLP compliance:
no
Other quality assurance:
ISO/IEC 17025 (General requirements for the competence of testing and calibration laboratories)
Type of method:
closed cup
Flash point apparatus:
Pensky-Martens apparatus

Test material

Constituent 1
Chemical structure
Reference substance name:
previous identifier no longer suitable
EC Number:
947-816-1
Cas Number:
00-00-0
Molecular formula:
previous identifier no longer suitable
IUPAC Name:
previous identifier no longer suitable
Test material form:
liquid

Results and discussion

Flash point
Key result
Flash point:
> 100 °C
Atm. press.:
1 013 hPa
Remarks on result:
no flash point up to 100°C

Applicant's summary and conclusion

Interpretation of results:
GHS criteria not met
Conclusions:
No flash point detected.