Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Physical & Chemical properties

Flash point

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
flash point of flammable liquids
Remarks:
Modified Continuously Closed Cup
Type of information:
experimental study
Adequacy of study:
key study
Study period:
20 February 2020 - 30 Jul 2020
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study
Qualifier:
according to guideline
Guideline:
other: ASTM D7094. Standard Test Method for Flash Point by Modified Continuously Closed Cup (MCCCFP) Tester
Version / remarks:
2012
Deviations:
no
GLP compliance:
yes (incl. QA statement)
Type of method:
closed cup
Flash point apparatus:
other: Eraflash flash-point tester (Eralytics, Vienna, Austria)
Specific details on test material used for the study:
Physical Description: Light orange liquid
Purity/Composition: UVCB
Storage Conditions: At room temperature protected from light
Purity/Composition correction factor: No correction factor required
Test item handling: Use amber glassware or wrap container in aluminum foil
Chemical name: 2,2-bis[({3-[methyl(phenyl)amino]propanoyl}oxy)methyl]butyl 3-[methyl(phenyl)amino]propanoate
Flash point:
196 °C
Atm. press.:
1 atm

Preliminary Test

The estimated flash-point of the test item was 193.0°C.

Main Study

The results of the main study on the determination of the flash-point of the test item are given in the table below.

The difference between the results obtained with the Test 1 and Test 2 was ≤ 6°C. From this, it was concluded that the flash-point of the test item is the lowest flash-point obtained.

Main Study: Flash-point of the Test Item

Test Flash-point Lowest flash-point
[°C] [°C]
1 197 196
2 196
Interpretation of results:
GHS criteria not met
Conclusions:
The closed cup method was applied for the determination of the flash-point of the test item.
The flash-point of the test item was 196°C.
Executive summary:
Information Guideline(s) Result Comment
Flash-point ASTM D7094 196°C closed cup method

Description of key information

Study conducted to recognised testing guidelines with GLP certification.

Key value for chemical safety assessment

Flash point at 101 325 Pa:
196 °C

Additional information