Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Physical & Chemical properties

Auto flammability

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
relative self-ignition temperature (solids)
Type of information:
experimental study
Adequacy of study:
key study
Study period:
2020-06-04 to 2020-06-29
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study
Qualifier:
according to guideline
Guideline:
EU Method A.16 (Relative Self-Ignition Temperature for Solids)
Version / remarks:
2008
Deviations:
no
GLP compliance:
yes (incl. QA statement)
Key result
Remarks on result:
no self ignition observed under the test conditions

In the course of this study the test item did not self-ignite up to 400 °C. Thus, no self-ignition temperature could be stated. A temperature/time curve is presented in the attached Figure.

Conclusions:
In the course of this study the test item did not self-ignite up to 400 °C.
Executive summary:

The study was conducted according to procedure and demands of EU-Method A. 16.The tests were started from ambient oven temperature. The temperature of the oven and sample were continuously recorded while the temperature of the oven was increased up to 400 °C.In the course of this study the test item did not self-ignite up to 400 °C. Thus, no self-ignition temperature could be stated.

Description of key information

In the course of this study the test item did not self-ignite up to 400 °C (reference 4.12 -1).

Key value for chemical safety assessment

Additional information

The study was conducted according to procedure and demands of EU-Method A. 16. The tests were started from ambient oven temperature. The temperature of the oven and sample were continuously recorded while the temperature of the oven was increased up to 400 °C. In the course of this study the test item did not self-ignite up to 400 °C. Thus, no self-ignition temperature could be stated.