Endpoint:
flash point of flammable liquids
Type of information:
experimental study
Adequacy of study:
key study
Study period:
2015
Reliability:
2 (reliable with restrictions)
Rationale for reliability incl. deficiencies:
guideline study without detailed documentation
Qualifier:
according to guideline
Guideline:
ASTM D93 (Standard test methods for flash point by pensky-martens closed cup tester)
Deviations:
not specified
GLP compliance:
not specified
Type of method:
closed cup
Flash point apparatus:
Pensky-Martens apparatus
Key result
Flash point:
> 212.5 °C
Remarks on result:
no flash point up to 100°C
Interpretation of results:
GHS criteria not met
Conclusions:
The flash point, measured with Pensky-Marten's Closed Cup according to ASTM D93 , exceeds 212.5 degrees Centigrade.
Executive summary:

The flash point, measured with Pensky-Marten's Closed Cup according to ASTM D93 , exceeds 212.5 degrees Centigrade. Thorough details of the method are not given.

Description of key information

The flash point of the test material, Santicizer P1700, measured with Pensky-Marten's Closed Cup apparatus according to ASTM D93, exceeds 212.5°C.

Key value for chemical safety assessment

Flash point at 101 325 Pa:
212.5 °C

Additional information

The flash point, measured with Pensky-Marten's Closed Cup according to ASTM D93 , exceeds 212.5 degrees Centigrade.