Registration Dossier

Diss Factsheets

Physical & Chemical properties

Vapour pressure

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
vapour pressure
Type of information:
experimental study
Adequacy of study:
key study
Study period:
2019
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study
Qualifier:
according to guideline
Guideline:
EU Method A.4 (Vapour Pressure)
Version / remarks:
Regulation 440/2009 last version updated 2019
GLP compliance:
no
Type of method:
static method
Key result
Test no.:
#1
Temp.:
ca. 20 °C
Vapour pressure:
ca. 0.6 kPa
Key result
Test no.:
#2
Temp.:
ca. 25 °C
Vapour pressure:
ca. 0.73 kPa
Key result
Test no.:
#3
Temp.:
ca. 50 °C
Vapour pressure:
ca. 1.1 kPa
Key result
Test no.:
#4
Temp.:
ca. 65 °C
Vapour pressure:
ca. 1.5 kPa
Key result
Test no.:
#5
Temp.:
ca. 75 °C
Vapour pressure:
ca. 1.63 kPa
Key result
Test no.:
#6
Temp.:
ca. 85 °C
Vapour pressure:
ca. 2.03 kPa
Key result
Test no.:
#7
Temp.:
ca. 95 °C
Vapour pressure:
ca. 2.33 kPa
Key result
Test no.:
#8
Temp.:
ca. 100 °C
Vapour pressure:
ca. 2.6 kPa

Description of key information

Key value for chemical safety assessment

Vapour pressure:
0.73 kPa
at the temperature of:
25 °C

Additional information