Registration Dossier

Administrative data

Endpoint:
flash point, other
Type of information:
experimental study
Adequacy of study:
key study
Study period:
31.07.2019
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Report date:
2019

Materials and methods

Test guideline
Qualifier:
according to guideline
Guideline:
ISO 2719 (Determination of flash point - Pensky-Martens closed cup method)
GLP compliance:
no
Type of method:
closed cup
Flash point apparatus:
Pensky-Martens apparatus

Test material

Reference
Name:
Unnamed
Type:
Constituent

Results and discussion

Flash point
Key result
Flash point:
ca. 123 °C
Atm. press.:
1.013 Bar

Applicant's summary and conclusion

Interpretation of results:
GHS criteria not met
Conclusions:
The flash point of the substance Isooctadecanoic acid, compound with dicyclohexylamine (1:1) is about 123°C according to DIN EN ISO 2719, Pensky
Martens closed cup method.