Registration Dossier

Diss Factsheets

Administrative data

Endpoint:
flash point of flammable liquids
Type of information:
experimental study
Adequacy of study:
key study
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
other: Conducted at GLP-accredited facility to current guidelines

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
2017
Report date:
2017

Materials and methods

Test guideline
Qualifier:
according to guideline
Guideline:
EU Method A.9 (Flash-Point)
Deviations:
no
GLP compliance:
yes (incl. QA statement)
Type of method:
closed cup

Test material

Constituent 1
Test material form:
liquid

Results and discussion

Flash point
Key result
Flash point:
> 98 °C
Atm. press.:
ca. 1 013 hPa

Applicant's summary and conclusion

Conclusions:
The test item DVSA 1 has no flash point up to 98 °C.
Executive summary:

The test item DVSA 1 has no flash point up to 98 °C.