Registration Dossier

Diss Factsheets

Administrative data

Endpoint:
melting point/freezing point
Type of information:
experimental study
Adequacy of study:
key study
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
2018
Report date:
2018

Materials and methods

Test guideline
Qualifier:
according to guideline
Guideline:
EU Method A.1 (Melting / Freezing Temperature)
GLP compliance:
yes (incl. QA statement)
Type of method:
differential scanning calorimetry

Test material

Constituent 1
Test material form:
liquid

Results and discussion

Melting / freezing point
Key result
Melting / freezing pt.:
>= -90 - <= 90 °C
Atm. press.:
1 013 hPa
Remarks on result:
other:
Remarks:
no melting between -90°C and 90°C. At a temperature of -26°C the test item shows a glass transition temperature (amorphous components)

Applicant's summary and conclusion

Conclusions:
The test item shows no melting between -90°C and 90°C. At a temperature of -26°C the test item shows a glass transition temperature (amorphous components).