Registration Dossier

Diss Factsheets

Administrative data

Endpoint:
vapour pressure
Type of information:
experimental study
Adequacy of study:
key study
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
2018
Report date:
2018

Materials and methods

Test guideline
Qualifier:
according to guideline
Guideline:
EU Method A.4 (Vapour Pressure)
GLP compliance:
yes (incl. QA statement)
Type of method:
other: DSC
Remarks:
DSC

Test material

Constituent 1
Test material form:
liquid

Results and discussion

Vapour pressureopen allclose all
Key result
Test no.:
#1
Temp.:
20 °C
Vapour pressure:
<= 0.12 Pa
Key result
Test no.:
#2
Temp.:
50 °C
Vapour pressure:
<= 1.9 Pa

Applicant's summary and conclusion

Conclusions:
The test item has vapour pressure of <= 0.12 Pa at 20°C and <= 1.9 Pa at 50°C.