Registration Dossier

Diss Factsheets

Administrative data

Endpoint:
flash point of flammable liquids
Type of information:
experimental study
Adequacy of study:
key study
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
2018
Report date:
2018

Materials and methods

Test guideline
Qualifier:
according to guideline
Guideline:
EU Method A.9 (Flash-Point)
GLP compliance:
yes (incl. QA statement)
Type of method:
closed cup
Flash point apparatus:
Setaflash apparatus

Test material

Constituent 1
Test material form:
liquid

Results and discussion

Flash point
Key result
Flash point:
190 °C
Atm. press.:
1 013 mBar

Applicant's summary and conclusion

Interpretation of results:
GHS criteria not met
Conclusions:
The test item shows a flash point at a temperature of 190°C.