Registration Dossier

Diss Factsheets

Physical & Chemical properties

Flash point

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
flash point of flammable liquids
Type of information:
experimental study
Adequacy of study:
key study
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study
Qualifier:
according to guideline
Guideline:
ASTM D93 (Standard test methods for flash point by pensky-martens closed cup tester)
GLP compliance:
no
Type of method:
closed cup
Flash point apparatus:
Pensky-Martens apparatus
Specific details on test material used for the study:
Reported as: Glyceryl Mono & Di-Formates
Key result
Flash point:
140 °C
Atm. press.:
ca. 1 atm
Conclusions:
The Flash Point of Glyceryl Mono & Di-Formates is 140 °C (PMCC)
Executive summary:

The Flash Point of Glyceryl Mono & Di-Formates is 140 °C (PMCC)

Description of key information

The flash point of the registered substance is concluded to be 140 °C (PMCC).

Key value for chemical safety assessment

Flash point at 101 325 Pa:
140 °C

Additional information