Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Physical & Chemical properties

Flash point

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
flash point of flammable liquids
Type of information:
experimental study
Adequacy of study:
key study
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study
Qualifier:
according to guideline
Guideline:
EU Method A.9 (Flash-Point)
Qualifier:
according to guideline
Guideline:
EPA OPPTS 830.6315 (Flammability)
GLP compliance:
yes (incl. QA statement)
Type of method:
closed cup
Flash point apparatus:
Setaflash apparatus
Key result
Flash point:
252 °C
Atm. press.:
102 kPa
Interpretation of results:
GHS criteria not met
Conclusions:
The flashpoint of the test mateiral is 252°C.
Executive summary:

The flashpoint of the test material is 252 ± 2 °C, using a closed cup equilibrium method designed to be compatible with Method A.9 Flash Point of Commission Regulation (EC) No 440/2008 of 30 May 2008.

Description of key information

The flashpoint of the test material is 252 ± 2 °C, using a closed cup equilibrium method designed to be compatible with Method A.9 Flash Point of Commission Regulation (EC) No 440/2008 of 30 May 2008.

Key value for chemical safety assessment

Flash point at 101 325 Pa:
252 °C

Additional information