Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Administrative data

Endpoint:
partition coefficient
Type of information:
experimental study
Adequacy of study:
key study
Study period:
12 February 2004
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
other: Study conducted in compliance with agreed protocols, with no or minor deviations from standard test guidelines and/or minor methodological deficiencies, which do not affect the quality of relevant results.
Cross-reference
Reason / purpose for cross-reference:
reference to other study

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
2004
Report date:
2004

Materials and methods

Test guideline
Qualifier:
according to guideline
Guideline:
EU Method A.8 (Partition Coefficient)
Deviations:
no
GLP compliance:
yes (incl. QA statement)
Remarks:
(Date of inspection: 02 December 2002 Date of signature: 13 February 2003)
Type of method:
HPLC method
Partition coefficient type:
octanol-water

Test material

Reference
Name:
Unnamed
Type:
Constituent
Details on test material:
- Name of test material (as cited in study report): TIPX
- Substance type: Colourless liquid.
- Physical state: Liquid.
- Lot/batch No.: 042028.
- Storage condition of test material: Approximately 4ºC in the dark.

Study design

Analytical method:
high-performance liquid chromatography

Results and discussion

Partition coefficient
Type:
log Pow
Partition coefficient:
> 6.2
Temp.:
25 °C
Details on results:
log Pow of > 6.2 at 25°C.

Any other information on results incl. tables

log Pow of > 6.2 at 25°C.

Applicant's summary and conclusion

Conclusions:
The partition coefficient of the test material has been determined to be >1.59 x 106, log10 Pow >6.20.
Executive summary:

Partition Coefficient has been determined to be >1.59 x 106, log10Pow, >6.20 using the HPLC method, Method A8 of Commission Directive 92/69/EEC.