Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Administrative data

First-aid measures

General:

Pay attention to self-protection. Remove victims from hazardous area.

Immediately remove soiled or soaked clothing and remove it to a safe distance.

Keep victim warm, in a stabilized position and covered.

Do not leave the victim unattended.

Place patients who are unconscious but breathing in the stabilized lateral position.

Description of first aid measures

Inhalation:

Inhalation is possible if aerosols, mists, dusts, or smoke form.

Move to fresh air.

With labored breathing: Provide with oxygen.

Consult a doctor immediately.

If the casualty is not breathing: Perform mouth-to-mouth resuscitation, notify emergency physician immediately.

Skin Contact:

Wash off affected area immediately with plenty of water for at least 15 minutes.

Get medical attention if any discomfort continues.

Eye contact:

With eye held open, thoroughly rinse immediately with plenty of water for at least 10 minutes.

In case of persistent discomfort: Consult an ophthalmologist.

Ingestion:

Rinse mouth.

Immediately give large quantities of water to drink.

Seek medical advice.

Most important symptoms and effects, both acute and delayed:

None known

Indication of any immediate medical attention and special treatment needed

Hazards:

Other dangerous properties cannot be excluded.

Treatment:

This product has not been completely analyzed yet and all health hazards might not be known.

Fire-fighting measures

Extinguishing media

Suitable extinguishing media:

Water spray, foam, CO2, dry powder.

Unsuitable extinguishing media:

Do not use a solid water stream as it may scatter and spread fire.

Special hazards arising from the substance or mixture:

May be released in case of fire: toxic gases/vapours.

Carbon Monoxide.

Carbon Dioxide.

Advice for firefighters Special fire fighting procedures:

Contaminated extinguishing water must be treated at a suitable disposal plant in accordance with waste management laws.

In case of fire, remove the endangered barrels and bring to a safe place, if this can be done safely.

Keep unauthorized personnel away.

Special protective equipment for fire-fighters:

In case of fire: full protective suit and wear a self contained respiratory apparatus.

Accidental release measures

Personal precautions, protective equipment and emergency procedures:

Keep unauthorized personnel away.

For non-emergency personnel:

No data available.

For emergency responders:

No data available.

Environmental Precautions:

Observe regulations on prevention of water pollution (check, dam up, cover up).

Do not allow entrance in sewage water, soil, stretches of water, drainage systems, surface water. If the product contaminates rivers and lakes or drains inform respective authorities.

Methods and material for containment and cleaning up:

Absorb with liquid-binding material, e. g.: chemisorption, diatomaceous earth, universal binder Transfer into suitable containers.

Clean contaminated surface thoroughly.

Pack and label wastes like the pure substance.

Do not detach label from the delivery containers prior to disposal.

Disposal according to local authority regulations.

Handling and storage

Precautions for safe handling:

Avoid residues of the product on the containers.

Avoid contact with eyes, skin, and clothing.

Handle in accordance with good industrial hygiene and safety practice.

Use permissible in closed systems only.

Handle and transfer product in closed systems only (gas displacement device).

Ensure that apparatus and pipelines are free from leaks.

Do not ventilate into the open.

Suitable loading and unloading device required.

All precautionary measures indicated have to be observed.

Risk assessment and risk monitoring of all work places required.

Health, Safety and Emergency Management System recommended.

Regular safety training is a must.

Written approval necessary in case of non-routine jobs, e.g. maintenance activities.

Conditions for safe storage, including any incompatibilities:

Normal measures for preventive fire protection.

Protect from sunlight, warmth and heat.

In order to ensure due transportation, make certain that stacks are of the correct height, containers are securely fastened so as not to fall off, and labelled according to the regulations. Store in the original receptable, keeping this tightly sealed, under cool and dry conditions.

Storage Class:

3: Flammable Liquids

Transport information

Land transport (UN RTDG/ADR/RID)

Shippingopen allclose all
Special provisions / remarks
Remarks:
Not permitted for transport.
Transport prohibited.

Inland waterway transport (UN RTDG/ADN(R))

Shippingopen allclose all
Special provisions / remarks
Remarks:
Not permitted for transport.
Transport prohibited.

Marine transport (UN RTDG/IMDG)

Shippingopen allclose all
Special provisions / remarks
Remarks:
Not permitted for transport.
Transport prohibited.

Air transport (UN RTDG/ICAO/IATA)

Shippingopen allclose all
Special provisions / remarks
Remarks:
Not permitted for transport.
Transport prohibited.
SpecialProvisionsopen allclose all

Exposure controls / personal protection

Control Parameters

Occupational Exposure Limits:

This Material is assigned to Evonik Exposure Control Band OEB 1 (range >10μg/m³ - 1000μg/m³)

Biological Limit Values:

No biological exposure limits noted for the ingredient(s).

DNEL-Values:

Remarks: No substance-related safety assessment is necessary / has been conducted for this product.

PNEC-Values:

Remarks: No substance-related safety assessment is necessary / has been conducted for this product.

Exposure controls Appropriate Engineering Controls:

Provide for installation of emergency shower and eye bath.

The substance must be handled under strictly controlled conditions in accordance with Article 17/18 of the REACH regulation.

Refill and handle product only in closed system.

Leak detection recommended.

Do not add wastewater to a biological wastewater treatment plant Minimization of emissions by means of suitable technical measures such as flanges and valves with low leakage rates, recirculation of vapours.

All precautionary measures indicated have to be observed.

Individual protection measures, such as personal protective equipment

Eye/face protection:

Safety glasses with side-shields conforming to EN166.

or

When handling larger quantities: basket-shaped glasses.

Hand Protection:

Material: Nitrile.

Glove thickness: 0.2 mm

Guideline: DIN EN 374

Material: Nitrile/Chloroprene

Glove thickness: 0.65 mm

Guideline: DIN EN 374

Additional Information: Accidental release measures

Additional Information: Selection of protective gloves to meet the requirements of specific workplaces.

Suitability for specific workplaces should be clarified with protective glove manufacturers.

The information is based on our own tests, references from the literature and information from glove manufacturers, or derived by analogy with similar materials.

Be aware that in daily use the durability of a chemical resistant protective glove can be notably shorter than the break through time measured according to EN 374, due to the numerous outside influences (e.g. temperature).

Skin and Body Protection:

Suitable protective clothing- Use disposable clothing if appropriate.

Respiratory Protection:

Respirator with ABEK combination filter Accidental release measures wear a self contained respiratory apparatus.

Note time limit for wearing respiratory protective equipment.

Hygiene measures:

Avoid contact with eyes and clothing.

Wash contact areas after handling.

Take off clothing and shoes contaminated with product.

Clean before reuse.

Do not eat, drink, smoke, or sniff while at work.

Wash your hands and/or face before breaks and before termination of work.

Environmental Controls:

In some cases, exhaust air scrubbers, filters or technical changes to the processing plant will be required in order to decrease emissions to acceptable values.

Stability and reactivity

Reactivity:

No further information available.

Chemical Stability:

No further information available.

Possibility of hazardous reactions:

No further information available.

Conditions to avoid:

No further information available.

Incompatible Materials:

No further information available.

Hazardous Decomposition Products:

Carbon Monoxide.

Carbon Dioxide.

Disposal considerations

Waste treatment methods

General information:

No data available.

Disposal methods:

The waste key number must be determined as per the European Waste Types List (decision on EU Waste Types List 2000/532/EC) in cooperation with the disposal firm / producing firm / official authority.

Strictly controlled conditions during disposal or treatment to air, wastewater and waste.

Do not add wastewater to a biological wastewater treatment plant Disposal according to local authority regulations.

Pack and label wastes like the pure substance.

Do not detach label from the delivery containers prior to disposal.

Contaminated Packaging:

Do not reuse empty containers and dispose of in accordance with the regulations issued by the appropriate local authorities.