Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
oxidising solids
Type of information:
experimental study
Adequacy of study:
key study
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study
Qualifier:
according to guideline
Guideline:
EU Method A.17 (Oxidising Properties (Solids))
GLP compliance:
yes (incl. QA statement)
Specific details on test material used for the study:
Batch 3033900250
Contact with:
powdered cellulose
Key result
Sample tested:
other: 2:1 sample to cellulose ratio
Parameter:
preliminary test
Remarks on result:
other: Test item/cellulose mix briefly ignited when in contact with ignition source (burner flame) and produced a small orange flame. Upon removal of the ignition source, there was no further propagation noticed and flame extinguished immediately.
Interpretation of results:
GHS criteria not met
Conclusions:
The oxidising properties of the substance were tested according to EU Method A.17. Test item/cellulose mix briefly ignited when in contact with ignition source (burner flame) and produced a small orange flame. Upon removal of the ignition source, there was no further propagation noticed and flame extinguished immediately. It is clear, that the test
item is not an oxidising solid.
Executive summary:

The oxidising properties of the substance were tested according to EU Method A.17. Test item/cellulose mix briefly ignited when in contact with ignition source (burner flame) and produced a small orange flame. Upon removal of the ignition source, there was no further propagation noticed and flame extinguished immediately. It is clear, that the test
item is not an oxidising solid.

Description of key information

The oxidising properties of the substance were tested according to EU Method A.17. Test item/cellulose mix briefly ignited when in contact with ignition source (burner flame) and produced a small orange flame. Upon removal of the ignition source, there was no further propagation noticed and flame extinguished immediately. It is clear, that the test
item is not an oxidising solid.

Key value for chemical safety assessment

Oxidising properties:
non oxidising

Additional information

Justification for classification or non-classification