Registration Dossier

Diss Factsheets

Physical & Chemical properties

Flash point

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
flash point of flammable liquids
Type of information:
experimental study
Adequacy of study:
key study
Study period:
Apr - Jul 2019
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study
Qualifier:
according to guideline
Guideline:
other: GB/T 261-2008
Deviations:
no
GLP compliance:
not specified
Other quality assurance:
other: Chinese Law Quality Inspection
Type of method:
closed cup
Flash point apparatus:
other: Closed-cup Flash Point Tester
Dynamic viscosity of test material:
no data
Specific details on test material used for the study:
Batch No.: 187-9-113-Y
Purity: 97.8%
Key result
Flash point:
200 °C
Atm. press.:
1 013 hPa
Interpretation of results:
GHS criteria not met
Conclusions:
The closed cup method was applied for the determination of the flash-point of the test item. The flash-point of the test item was 200°C.

Description of key information

The closed cup method was applied for the determination of the flash-point of the test item. The flash-point of the test item was 200°C.

Key value for chemical safety assessment

Flash point at 101 325 Pa:
200 °C