Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Physical & Chemical properties

Particle size distribution (Granulometry)

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
particle size distribution (granulometry)
Type of information:
experimental study
Adequacy of study:
key study
Reliability:
1 (reliable without restriction)
Qualifier:
according to guideline
Guideline:
ISO 13320 (Particle size analysis - Laser diffraction methods)
Version / remarks:
2009
Deviations:
no
GLP compliance:
no
Type of method:
Laser scattering/diffraction
Type of distribution:
volumetric distribution
Mass median aerodynamic diameter:
20.4 µm
Geometric standard deviation:
2.397
Key result
Percentile:
D10
Mean:
5.48 µm
St. dev.:
0.098
Key result
Percentile:
D50
Mean:
17.6 µm
St. dev.:
0.154
Key result
Percentile:
D90
Mean:
48 µm
St. dev.:
0.626
Conclusions:
The particle size distribution is determined as: D10 is 5.48 um, D50 is 17.6 um, D90 is 48 um. MMAD is 20.4 um.

Description of key information

The particle size distribution is determined as: D10 is 5.48 um, D50 is 17.6 um, D90 is 48 um. MMAD is 20.4 um.

Additional information