Physical & Chemical properties

Flammability

Currently viewing:

Administrative data

Link to relevant study record(s)

Referenceopen allclose all

Endpoint:
flammable solids
Type of information:
experimental study
Adequacy of study:
key study
Study period:
2021-06-02
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study
Qualifier:
according to guideline
Guideline:
EU Method A.10 (Flammability (Solids))
GLP compliance:
no
Key result
Test procedure:
burning rate test: preliminary screening test
Remarks on result:
substance does not ignite and propagate combustion either by burning with flame or smouldering along 200 mm of the powder train within the 2 minutes test period

Preliminary test


The test item could not be ignited with a flame. The test item melted. The performance of the main test was not necessary.

Interpretation of results:
not classified based on GHS criteria
Conclusions:
The test substance couldn't be ignited with a flame. Therefore the full test programme (main test) was not carried out and the test substance was not classified as flammable.
Executive summary:

A preliminary test according to EC Directive, Part A, Methods for the determination of physico-chemical properties, A.10 was performed to determine the flammability of the test substance. The test item was formed into a powder train. The flame from a gas burner was applied to one end of the powder train for 2 minutes. The burning of the pile was observed. In the preliminary test the test item could not be ignited. Based on the results of the preliminary test, no main test was performed. The test item is considered as a not readily combustible solid of Division 4.1. and is not a flammable solid.

Endpoint:
flammable gases
Data waiving:
study technically not feasible
Justification for data waiving:
the study does not need to be conducted because the substance is a solid
Endpoint:
pyrophoric liquids
Data waiving:
study technically not feasible
Justification for data waiving:
the study does not need to be conducted because the substance is a solid
Endpoint:
pyrophoric solids
Data waiving:
study scientifically not necessary / other information available
Justification for data waiving:
the study does not need to be conducted because the substance is known to be stable in contact with air at room temperature for prolonged periods of time (days) and hence, the classification procedure does not need to be applied
Endpoint:
substances / mixtures which in contact with water emit flammable gases
Data waiving:
study scientifically not necessary / other information available
Justification for data waiving:
the study does not need to be conducted because the experience in production or handling shows that the substance does not react with water, e.g. the substance is manufactured with water or washed with water

Description of key information

The substance is not considered as flammable gas, flammable solid, flammable in contact with water, pyrophoric, and self-heating substance.

Key value for chemical safety assessment

Additional information

Flammable solids


A preliminary test according to Regulation (EC) No 440/2008 method A.10 was performed to determine the flammability of the test substance. The test item was formed into a powder train. The flame from a gas burner was applied to one end of the powder train for 2 minutes. The burning of the pile was observed. The test was performed twice. In the preliminary test the test item could not be ignited. Based on the results of the preliminary test, no main test was performed. The test item is considered as a not readily combustible solid of Division 4.1. and is not a flammable solid.


 


Flammable gases


The test item is a solid at ambient conditions. This hazard class is only applicable for gases. Thus, the substance was not considered for classification as flammable gas.


 


Flammable liquids


The test item is a solid at ambient conditions. This hazard class is only applicable for liquids. Thus, the substance was not considered for classification as flammable liquid.


 


Pyrophoric liquids 


The test item is a solid at ambient conditions. This hazard class is only applicable for liquids. Thus, the substance was not considered for classification as pyrophoric liquid.


 


Pyrophoric solids


In accordance with section 2.9.4 Annex I of Regulation (EC) No 1272/2008 and ECHA guidance on the application of CLP Criteria section 2.10.4.2 the classification procedure for pyrophoric solids need not be applied when experience in manufacturing or handling shows that the substance or mixture does not ignite spontaneously when coming into contact with air at normal temperatures. Based on the experience in handling and use the substance is not known to ignite spontaneously when coming into contact with air at normal temperatures. Thus, no study was conducted and the substance was not considered for classification as pyrophoric solid.


 


Self-heating substances/mixture


No self-ignition temperature was observed up to the maximum test temperature of 401°C, according to the testing guideline for auto-flammability (solids - determination of relative self-ignition temperature) in the sense of the European Commission Regulation (EC) No.440/2008, Method A.16.

Justification for classification or non-classification