Registration Dossier
Registration Dossier
Diss Factsheets
Use of this information is subject to copyright laws and may require the permission of the owner of the information, as described in the ECHA Legal Notice.
EC number: 864-951-0 | CAS number: 2170099-74-6
- Life Cycle description
- Uses advised against
- Endpoint summary
- Appearance / physical state / colour
- Melting point / freezing point
- Boiling point
- Density
- Particle size distribution (Granulometry)
- Vapour pressure
- Partition coefficient
- Water solubility
- Solubility in organic solvents / fat solubility
- Surface tension
- Flash point
- Auto flammability
- Flammability
- Explosiveness
- Oxidising properties
- Oxidation reduction potential
- Stability in organic solvents and identity of relevant degradation products
- Storage stability and reactivity towards container material
- Stability: thermal, sunlight, metals
- pH
- Dissociation constant
- Viscosity
- Additional physico-chemical information
- Additional physico-chemical properties of nanomaterials
- Nanomaterial agglomeration / aggregation
- Nanomaterial crystalline phase
- Nanomaterial crystallite and grain size
- Nanomaterial aspect ratio / shape
- Nanomaterial specific surface area
- Nanomaterial Zeta potential
- Nanomaterial surface chemistry
- Nanomaterial dustiness
- Nanomaterial porosity
- Nanomaterial pour density
- Nanomaterial photocatalytic activity
- Nanomaterial radical formation potential
- Nanomaterial catalytic activity
- Endpoint summary
- Stability
- Biodegradation
- Bioaccumulation
- Transport and distribution
- Environmental data
- Additional information on environmental fate and behaviour
- Ecotoxicological Summary
- Aquatic toxicity
- Endpoint summary
- Short-term toxicity to fish
- Long-term toxicity to fish
- Short-term toxicity to aquatic invertebrates
- Long-term toxicity to aquatic invertebrates
- Toxicity to aquatic algae and cyanobacteria
- Toxicity to aquatic plants other than algae
- Toxicity to microorganisms
- Endocrine disrupter testing in aquatic vertebrates – in vivo
- Toxicity to other aquatic organisms
- Sediment toxicity
- Terrestrial toxicity
- Biological effects monitoring
- Biotransformation and kinetics
- Additional ecotoxological information
- Toxicological Summary
- Toxicokinetics, metabolism and distribution
- Acute Toxicity
- Irritation / corrosion
- Sensitisation
- Repeated dose toxicity
- Genetic toxicity
- Carcinogenicity
- Toxicity to reproduction
- Specific investigations
- Exposure related observations in humans
- Toxic effects on livestock and pets
- Additional toxicological data
Administrative data
First-aid measures
If inhaled : fresh air.
In case of skin contact : Take off immediately all contaminated clothing. Rinse skin with water/ shower. Consult a physician.
In case of eye contact : rinse out with plenty of water. Remove contact lenses.
If swallowed : immediately make victim drink water (two glasses at most).
Fire-fighting measures
Extinguishing media
Suitable extinguishing media: Water, Foam, Carbon dioxide (CO2), Dry powder
Unsuitable extinguishing media: For this substance/mixture no limitations of extinguishing
agents are given.
Special hazards arising from the substance or mixture
Specific hazards during firefighting: Combustible.
Vapours are heavier than air and may spread along floors.
Forms explosive mixtures with air on intense heating.
Development of hazardous combustion gases or vapours
possible in the event of fire.
Fire may cause evolution of: Sulphur oxides, Hydrogen fluoride
Advice for firefighters
Special protective equipmentfor firefighters: Stay in danger area only with self-contained breathing apparatus. Prevent skin contact by keeping a safe distance or by wearing suitable protective clothing.
Further information: Prevent fire extinguishing water from contaminating surface
water or the ground water system.
Suppress (knock down) gases/vapours/mists with a water spray jet.
Accidental release measures
Personal precautions, protective equipment and emergency procedures
Personal precautions : Advice for non-emergency personnel: Do not breathe vapours, aerosols.
Avoid substance contact.
Ensure adequate ventilation.
Evacuate the danger area, observe emergency procedures, consult an expert.
Environmental precautions: Do not flush into surface water or sanitary sewer system.
Methods and material for containment and cleaning up
Methods for cleaning up : Cover drains. Collect, bind, and pump off spills.
Observe possible material restrictions.
Take up with liquid-absorbent material (e.g. Chemizorb® ).
Dispose of properly. Clean up affected area.
Handling and storage
Precautions for safe handling
Advice on safe handling : Observe label precautions.
Hygiene measures : Immediately change contaminated clothing. Apply preventive skin protection. Wash hands and face after working with substance.
Conditions for safe storage, including any incompatibilities
Requirements for storage areas and containers: Store in original container.
Further information on storage conditions: Tightly closed.
Recommended storage temperature: Recommended storage temperature see product label.
Transport information
Shippingopen allclose all
SpecialProvisionsopen allclose all
Shippingopen allclose all
Remarksopen allclose all
Marine transport (UN RTDG/IMDG)
Shippingopen allclose all
Remarksopen allclose all
Shippingopen allclose all
Remarksopen allclose all
SpecialProvisionsopen allclose all
Exposure controls / personal protection
Engineering measures:
Technical measures and appropriate working operations should be given priority over the use of
personal protective equipment.
Personal protective equipment:
Protective clothing needs to be selected specifically for the workplace, depending on
concentrations and quantities of the hazardous substances handled and must meet the
specifications of a standard EN/ISO/DIN. The chemical resistance of the protective equipment
should be enquired at the respective supplier.
Eye protection : Safety glasses
Hand protection : required
Protective measures : Protective clothing
Respiratory protection : required when vapours/aerosols are generated.
Recommended Filter type: : ABEK-filter
The entrepreneur has to ensure that maintenance, cleaning and testing of respiratory protective
devices are carried out according to the instructions of the producer. These measures have to be
properly documented.
Environmental exposure controls:
General advice : Do not flush into surface water or sanitary sewer system.
Stability and reactivity
Reactivity:
Forms explosive mixtures with air on intense heating.
A range from approx. 15 Kelvin below the flash point is to be rated as critical.
Chemical stability:
The product is chemically stable under standard ambient conditions (room temperature) .
Possibility of hazardous reactions:
Hazardous reactions : Violent reactions possible with: Strong oxidizing agents
Conditions to avoid : Strong heating.
Materials to avoid : no information available
Disposal considerations
According to national guidelines and regulations.
Information on Registered Substances comes from registration dossiers which have been assigned a registration number. The assignment of a registration number does however not guarantee that the information in the dossier is correct or that the dossier is compliant with Regulation (EC) No 1907/2006 (the REACH Regulation). This information has not been reviewed or verified by the Agency or any other authority. The content is subject to change without prior notice.
Reproduction or further distribution of this information may be subject to copyright protection. Use of the information without obtaining the permission from the owner(s) of the respective information might violate the rights of the owner.