Administrative data

Endpoint:
oxidising solids
Type of information:
not specified
Adequacy of study:
disregarded due to major methodological deficiencies
Study period:
2005
Reliability:
3 (not reliable)
Rationale for reliability incl. deficiencies:
documentation insufficient for assessment

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
2005
Report date:
2005

Materials and methods

Test guideline
Qualifier:
according to guideline
Guideline:
other: Directive 92/69/EEC, Method A.17, estimation method.
Principles of method if other than guideline:
The test procedure described in 92/69/EEC, method A.17 need not be carried out when examination of the structural formula established beyond reasonable doubt that the substance has no oxidising properties. The test substance contains one oxygen atom which is only bonded to carbon. The oxygen balance is -194. Therefore oxidizing properties of "STI571 F8" are unlikely.
GLP compliance:
yes

Test material

Constituent 1
Test material form:
solid: particulate/powder
Details on test material:
Batch number: 022401

Study design

Contact with:
other: The test procedure described in 92/69/EEC, method A.17 need not be carried out when examination of the structural formula established beyond reasonable doubt that the substance has no oxidising properties.

Results and discussion

Test results (Oxidising solids)
Key result
Sample tested:
other: Not applicable
Parameter:
other:
Remarks on result:
not measured/tested
Remarks:
The test substance contains one oxygen atom which is only bonded to carbon. The oxygen balance is -194.

Applicant's summary and conclusion

Interpretation of results:
GHS criteria not met
Conclusions:
The test substance contains one oxygen atom which
is only bonded to carbon.
The oxygen balance is -194. Therefore oxidizing properties of "STI571 F8" are
unlikely.