Registration Dossier

Diss Factsheets

Physical & Chemical properties

Vapour pressure

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
vapour pressure
Data waiving:
study scientifically not necessary / other information available
Justification for data waiving:
the study does not need to be conducted because the melting point is above 300°C

Description of key information

Data waiving (study scientifically not necessary / other information available):
The study does not need to be conducted because the melting point of cerium gadolinium oxide is above 300 °C.

Key value for chemical safety assessment

Additional information

A GLP-compliant study, performed according to OECD TG 102, scored as Klimisch 1 and selected as a key study in IUCLID section 4.2, shows no melting point of cerium gadolinium oxide up to and including 600 °C.