Registration Dossier

Diss Factsheets

Physical & Chemical properties

Flash point

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
flash point of flammable liquids
Type of information:
experimental study
Adequacy of study:
key study
Study period:
February 2022
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study
Qualifier:
according to guideline
Guideline:
EU Method A.9 (Flash-Point)
GLP compliance:
no
Type of method:
non-equilibrium method closed cup
Flash point apparatus:
Pensky-Martens apparatus
Remarks:
Pensky-Martens apparatus- ASTM D93-20 Proc. B
Dynamic viscosity of test material:
The mean viscosities are:
- Viscosity at 25°C: 1796 mm2/s;
- Viscosity at 40°C: 483 mm2/s.
Key result
Flash point:
> 190 °C
Atm. press.:
ca. 1 atm
Interpretation of results:
GHS criteria not met
Conclusions:
Flash point > 190°C, temperature of decomposition of sample
Executive summary:

Flash point has been determined using close cup method, Pensky-Martens apparatus- ASTM D93-20 Proc. B. The flash point was > 190°C, this is the decomposition temperature of sample. 

Description of key information

Flash point > 190°C, that is the decomposition temperature of sample

Key value for chemical safety assessment

Additional information