Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Physical & Chemical properties

Viscosity

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
viscosity
Type of information:
experimental study
Adequacy of study:
key study
Study period:
16 February 2022
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study
Qualifier:
according to guideline
Guideline:
ASTM D-445 (Standard Test Method for Kinematic Viscosity of Transparent and Opaque Liquids (and Calculation of Dynamic Viscosity)
GLP compliance:
not specified
Type of method:
other: viscometer of Cannon Fenske model ROUTINE
Key result
Temp.:
40°C
Parameter:
kinematic viscosity (in mm²/s)
Value:
ca. 483
Key result
Temp.:
other: 25°C
Parameter:
kinematic viscosity (in mm²/s)
Value:
ca. 1 796
Conclusions:
The mean viscosities are:
- Viscosity at 25°C: 1796 mm2/s;
- Viscosity at 40°C: 483 mm2/s.
The % of deviation is 0,2% per each couple of measurements.
Executive summary:

This study was carried out to determine the kinematic viscosity at 25 °C and 40 °C of ESSEBIOCHLOR45 using the viscometer of Cannon Fenske model ROUTINE according to method ASTM D445-19. Analysis were performed twice per viscosity at 25°C and 40°C.
Results of analysis are:
- Viscosity at 25°C: 1796 cSt
- Viscosity at 40°C: 483 cSt

Description of key information

The mean viscosity was 1796 mm2/s and 483 mm2/s at 25° and 40°C, respectively.

Key value for chemical safety assessment

Viscosity:
483 mm²/s (static)
at the temperature of:
40 °C

Additional information