Registration Dossier

Diss Factsheets

Administrative data

Endpoint:
flash point of flammable liquids
Type of information:
experimental study
Adequacy of study:
key study
Study period:
04-May to 30-May-2006
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
2006
Report date:
2006

Materials and methods

Test guideline
Qualifier:
according to guideline
Guideline:
EU Method A.9 (Flash-Point)
GLP compliance:
yes (incl. QA statement)
Remarks:
Hess. Ministerium fur Umwelt, ländlichen Raum und Verbraucherschutz, Wiesbaden, Germany
Type of method:
closed cup
Flash point apparatus:
Pensky-Martens apparatus

Test material

Reference
Name:
Unnamed
Type:
Constituent
Test material form:
liquid

Results and discussion

Flash point
Flash point:
116 °C
Atm. press.:
1 013 hPa

Applicant's summary and conclusion

Interpretation of results:
study cannot be used for classification
Conclusions:
The flash point of the test item was determined to be 116.0 °C at 1013 hPa according to EU Method A.9.