Administrative data

First-aid measures

Emergency measure - Inhalation: Remove the person from exposure to the product.  If not

breathing give artificial respiration and call a physician.

Emergency measure - Eyes: Eye irritation may occur.  Immediately flush the eyes with

plenty of water for at least 15 minutes.  Call a physician.

Emergency measure - Skin: Wash the skin thoroughly with soap and water.

Emergency measure - Ingestion: If swallowed do not induce vomiting.  Get prompt medical

attention.

Fire-fighting measures

Recommended extinguishing agent: alcohol foam, dry chemical

Product arising from burning: The exact nature of the combustion gases is not known.  They

would include carbon dioxide and carbon monoxide.

Protective equipment: Fire fighters should use protective equipment including self

contined breathing apparatus.  Workers contacting the

product should wear safety glasses and impermeable gloves.

Accidental release measures

Emergency measures in case of spillage: Use appropriate protective equipment when working with

spills.  All spills should be contained to prevent

contamination of surrounding areas.  Soak up the spill with

sawdust, sand or other absorbent material.  Flush the area

with water.

Handling and storage

Handling: When handling this product it is recommended that personal

protection equipment be used including safety glasses and

impermeable gloves.

Avoid breathing the vapors or mist.  The use of mechanical

ventilation is recommended whenever this product is used in

a confined space or heated above ambient temperature.

Storage: This product should be stored in a closed container at

ambient temperature.  The storage area should be well

ventilated and away from moisture.

Packaging of the substance and or preparation: This product is packaged in 5-gallon HDPE pails, 55-gallon

lined steel drums and in stainless steel tank trucks.

Transport information

Shippingopen allclose all
SpecialProvisionsopen allclose all
Shippingopen allclose all
Remarksopen allclose all

Marine transport (UN RTDG/IMDG)

Shippingopen allclose all
Remarksopen allclose all

Air transport (UN RTDG/ICAO/IATA)

Shippingopen allclose all
Special provisions / remarks
Remarks:
Transport: This product is non-hazardous according to DOT regulations
and is shipped as "Synthetic Plastic Plasticizer". The
product is shipped in 5-gallon polyethylene pails, lined
steel drums and stainless steel tank trucks.


International Harmonized Code: 2918.15.0000.0
SpecialProvisionsopen allclose all

Exposure controls / personal protection

Personal Protective Equipment: Chemical goggles; face shields if necessary. Work uniforms or impervious clothing and boots.  Neoprene, nitrile or PVC-coated gloves. Where overexposures are a concern, use NIOSH-approved chemical cartridge respirator or supplied-air breathing equipment as necessary.

Respirator Caution: Observe OSHA regulations for respirator use (29 CFR 1910.134). Air-purifying respirators must not be used in oxygen-deficient atmospheres.

Ventilation: All operations should be conducted in well-ventilated conditions. Local exhaust ventilation should be provided.

Other Engineering Controls: All appropriate engineering controls should be used to minimize exposure potential. Use exhaust ventilation to keep airborne concentrations below exposure limits.

Thermal Hazards: Not applicable.

Additive or Synergistic Effects: None known.

Stability and reactivity

Danger other than fire: None known

Chemical reaction with water: This product does not react with water.

Dust explosion: Product is an oily liquid.

Disposal considerations

Industry - Possibility of recovery/recycling: No possibility that the used agent will be recovered.

Industry - Possibility of neutralisation: Agent has no potentially hazardous effect.  The agent is

essentially harmless toxicologically and environmentally.

Industry - Possibility of destruction: controlled discharge: Agent could be discharged in a controlled manner but the

necessity for this kind of destruction is quite remote.

Industry - Possibility of destruction - incineration: The agent could be incinerated but the necessity for this

kind of destruction is quite remote.

Industry - Possibility of destruction - water purification: not applicable

Public at large - Possibility of recovery/recycling: The agent will be completely limited to an industrial use as

a plasticizer in extruded medical grade plastics.  The

public will not have any contact with the agent.

Public at large - Possibility of neutralisation: not applicable

Public at large - Possibility of destruction: controlled discharge: not applicable

Public at large - Possibility of destruction - incineration: not applicable

Public at large - Possibility of destruction - water purification: not applicable

Public at large - Possibility of destruction - others: not applicable