Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Physical & Chemical properties

Flash point

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
flash point of flammable liquids
Type of information:
experimental study
Adequacy of study:
key study
Study period:
27 May 2021 - 02 June 2021
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
other: Study performed according to EU A.9 guideline, under GLP, without deviation and with certificate of analysis included.
Reason / purpose for cross-reference:
reference to other study
Reason / purpose for cross-reference:
reference to same study
Qualifier:
according to guideline
Guideline:
EU Method A.9 (Flash-Point)
Deviations:
not specified
GLP compliance:
no
Type of method:
equilibrium method closed cup
Flash point apparatus:
Setaflash apparatus
Flash point:
51.7 °C
Atm. press.:
101.3 kPa
Remarks on result:
other: First determination
Flash point:
51.8 °C
Atm. press.:
101.3 kPa
Remarks on result:
other: Second determination
Flash point:
51.8 °C
Atm. press.:
101.3 kPa
Remarks on result:
other: Third determination
Key result
Flash point:
51.8 °C
Atm. press.:
ca. 101.3 kPa
Remarks on result:
other: Mean of the three determinations

Results:


Available Data for Reference Item: 


Fash point of Miniflash Certified Material 0902INFO2 by two references:


























 Flash point 1 (°C)Flash point 2 (°C)Flash point 3 (°C)theoretical value (°C)
anisole (batch AN04000250)42.042.042.543.3 +/- 1.5
Dodecane
(batch A0375076)
79.078.878.978.8 +/- 2.1

 


According to the results obtained with the reference items, the test has to be considered as valid.


Measured values and Validation of the Study:


The measured values are given in the table below:


Table 1: Measured flash point of the test item and reference item (°C):



















 Flash point 1 (°C)Flash point 2 (°C)Flash point 3 (°C)Mean Flash point (°C)
REACTION MASS OF 1,4-CINEOLE, 1,8-CINEOLE, DL-LIMONENE AND TERPINOLENE51.751.851.851.8

 

Conclusions:
The flash point of REACTION MASS OF 1,4-CINEOLE, 1,8-CINEOLE, DL-LIMONENE AND TERPINOLENE was determined to be 51.8°C.
Executive summary:

The purpose of the study was to determine the flash point of substance REACTION MASS OF 1,4-CINEOLE, 1,8-CINEOLE, DL-LIMONENE AND TERPINOLENE.


The determination of the flash point was performed in accordance with Regulation (EC) No 440/2008, method A.9 “Flash Point” (May 2008) and the Standard Test Method ASTM D 3828-97.
Three measurements were performed.



The flash point of REACTION MASS OF 1,4-CINEOLE, 1,8-CINEOLE, DL-LIMONENE AND TERPINOLENE was determined to be 51.8°C.


 


 


 


 


 

Description of key information

The flash point of REACTION MASS OF 1,4-CINEOLE, 1,8-CINEOLE, DL-LIMONENE AND TERPINOLENE was determined to be 51.8°C.

Key value for chemical safety assessment

Flash point at 101 325 Pa:
51.8 °C

Additional information

Company internal data.