Registration Dossier
Registration Dossier
Diss Factsheets
Use of this information is subject to copyright laws and may require the permission of the owner of the information, as described in the ECHA Legal Notice.
EC number: 212-084-8 | CAS number: 760-93-0
- Life Cycle description
- Uses advised against
- Endpoint summary
- Appearance / physical state / colour
- Melting point / freezing point
- Boiling point
- Density
- Particle size distribution (Granulometry)
- Vapour pressure
- Partition coefficient
- Water solubility
- Solubility in organic solvents / fat solubility
- Surface tension
- Flash point
- Auto flammability
- Flammability
- Explosiveness
- Oxidising properties
- Oxidation reduction potential
- Stability in organic solvents and identity of relevant degradation products
- Storage stability and reactivity towards container material
- Stability: thermal, sunlight, metals
- pH
- Dissociation constant
- Viscosity
- Additional physico-chemical information
- Additional physico-chemical properties of nanomaterials
- Nanomaterial agglomeration / aggregation
- Nanomaterial crystalline phase
- Nanomaterial crystallite and grain size
- Nanomaterial aspect ratio / shape
- Nanomaterial specific surface area
- Nanomaterial Zeta potential
- Nanomaterial surface chemistry
- Nanomaterial dustiness
- Nanomaterial porosity
- Nanomaterial pour density
- Nanomaterial photocatalytic activity
- Nanomaterial radical formation potential
- Nanomaterial catalytic activity
- Endpoint summary
- Stability
- Biodegradation
- Bioaccumulation
- Transport and distribution
- Environmental data
- Additional information on environmental fate and behaviour
- Ecotoxicological Summary
- Aquatic toxicity
- Endpoint summary
- Short-term toxicity to fish
- Long-term toxicity to fish
- Short-term toxicity to aquatic invertebrates
- Long-term toxicity to aquatic invertebrates
- Toxicity to aquatic algae and cyanobacteria
- Toxicity to aquatic plants other than algae
- Toxicity to microorganisms
- Endocrine disrupter testing in aquatic vertebrates – in vivo
- Toxicity to other aquatic organisms
- Sediment toxicity
- Terrestrial toxicity
- Biological effects monitoring
- Biotransformation and kinetics
- Additional ecotoxological information
- Toxicological Summary
- Toxicokinetics, metabolism and distribution
- Acute Toxicity
- Irritation / corrosion
- Sensitisation
- Repeated dose toxicity
- Genetic toxicity
- Carcinogenicity
- Toxicity to reproduction
- Specific investigations
- Exposure related observations in humans
- Toxic effects on livestock and pets
- Additional toxicological data

Boiling point
Administrative data
Link to relevant study record(s)
- Endpoint:
- boiling point
- Type of information:
- experimental study
- Adequacy of study:
- key study
- Reliability:
- 1 (reliable without restriction)
- Rationale for reliability incl. deficiencies:
- guideline study
- Remarks:
- OECD 103, GLP
- Principles of method if other than guideline:
- Method: differential scanning calorimetry
In a measurement with differential scanning calorimetry (DSC) a sample of the test item and a reference material (identical crucible without the test
item) are subjected to the same controlled temperature program. The difference in the temperatures of the test item and the reference
material is the original measurement signal which is internally assigned to the heat flow rate. The heat flux DSC belongs to the class of heat-
exchanging calorimeters. A defined exchange of the heat to be measured takes place via a thermal resistance. In contrast in the power
compensation DSC, the heat to be measured is compensated with electric energy, by increasing or decreasing an adjustable heating power.
When the sample undergoes a transition involving a change in enthalpy, for example an endothermic melting or boiling transition that change is
indicated by a departure from the base line of the heat flow record. The peak area is proportional to the change in enthalpy. - GLP compliance:
- yes
- Type of method:
- differential scanning calorimetry
- Key result
- Boiling pt.:
- 197 °C
- Atm. press.:
- 1 002.1 hPa
- Conclusions:
- The boiling temperature of the test item was determined by differential scanning calorimetry according to EEC-Directive 92/69 EEC, Part A,
Methods for the determination of physico-chemical properties, A.2 "Boiling temperature", EEC Publication No. L383, December 1992.
The extrapolated Boiling Point was determined to be 197 °C at 1002.1 hPa. - Executive summary:
The boiling temperature of the test item was determined by differential scanning calorimetry according to EEC-Directive 92/69 EEC, Part A, Methods for the determination of physico-chemical properties, A.2 "Boiling temperature", EEC Publication No. L383, December 1992. The extrapolated Boiling Point was determined to be 197 °C at 1002.1 hPa.
NOTE: Any of data in this dataset are disseminated by the European Union on a right-to-know basis and this is not a publication in the same sense as a book or an article in a journal. The right of ownership in any part of this information is reserved by the data owner(s). The use of this information for any other, e.g. commercial purpose is strictly reserved to the data owners and those persons or legal entities having paid the respective access fee for the intended purpose.
Reference
Equipment:
Dynamic Differential Scanning Calorimeter Mettler DSC 820
Thermo balance Netzsch TG 209
Analytical balance (accuracy 0.01 mg)
Mercury barometer type 604
Parameters:
Differential scanning calorimeter | |
Crucible: | aluminum, 40 µl, lid with hole |
Purge gas: | nitrogen, 50 ml/min |
Cooling: | liquid nitrogen |
Heating rate: | 10 K/min |
Temperature range: | -150 to 0 °C Melting point |
Sample amount: | 5.11 / 5.94 mg |
Atmospheric Pressure: | 1002.1 hPa |
Description of key information
EEC-Directive 92/69 EEC, Part A, Methods for the determination of physico-chemical properties, A.2 "Boiling
temperature", EEC Publication No. L383, December 1992. The extrapolated Boiling Point was determined to be 197 °C at 1002.1 hPa.
Key value for chemical safety assessment
- Boiling point at 101 325 Pa:
- 197 °C
Additional information
Information on Registered Substances comes from registration dossiers which have been assigned a registration number. The assignment of a registration number does however not guarantee that the information in the dossier is correct or that the dossier is compliant with Regulation (EC) No 1907/2006 (the REACH Regulation). This information has not been reviewed or verified by the Agency or any other authority. The content is subject to change without prior notice.
Reproduction or further distribution of this information may be subject to copyright protection. Use of the information without obtaining the permission from the owner(s) of the respective information might violate the rights of the owner.