Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Administrative data

Endpoint:
vapour pressure
Type of information:
(Q)SAR
Adequacy of study:
key study
Reliability:
2 (reliable with restrictions)
Rationale for reliability incl. deficiencies:
other: calculated result with MPBPVP Program (v1.43) by using EPIWIN Suite 4.0 software package of US EPA
Justification for type of information:
QSAR prediction: migrated from IUCLID 5.6

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
2013
Report date:
2013

Materials and methods

Test guideline
Qualifier:
equivalent or similar to guideline
Guideline:
other: QSAR-method
Deviations:
yes
Remarks:
QSAR-method
Principles of method if other than guideline:
calculated result with MPBPVP Program (v1.43) by using EPIWIN Suite 4.0 software package of US EPA
GLP compliance:
no
Type of method:
other: QSAR-method

Test material

Constituent 1
Reference substance name:
32085-79-3
EC Number:
608-700-3
Cas Number:
32085-79-3
IUPAC Name:
32085-79-3

Results and discussion

Vapour pressureopen allclose all
Temp.:
25 °C
Vapour pressure:
0 mm Hg
Remarks on result:
other: Modified Grain Method
Temp.:
25 °C
Vapour pressure:
0 Pa
Remarks on result:
other: Modified Grain Method

Any other information on results incl. tables

calculated result with MPBPVP Program (v1.43) by using EPIWIN Suite 4.0 software package of US EPA

Applicant's summary and conclusion

Conclusions:
result of vapour pressure shows 9.61E-008 mm Hg (Modified Grain Method) at 25°C and 1.28E-005 Pa (Modified Grain Method) at 25°C (calculated
result with MPBPVP Program (v1.43) by using EPIWIN Suite 4.0 software package of US EPA)