Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Administrative data

Endpoint:
viscosity
Type of information:
experimental study
Adequacy of study:
key study
Study period:
from July 04,2008 to October 07,2008
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
other: In compliance with the Good Laboratory Practice Standards (Directive 2004/10/EC – French decree No. 2006-1523) and the Standard Operating Procedures in use at DEFITRACES.

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
2008
Report date:
2008

Materials and methods

Test guidelineopen allclose all
Qualifier:
according to guideline
Guideline:
OECD Test Guideline 114 (Viscosity of Liquids)
Deviations:
no
Qualifier:
according to guideline
Guideline:
other: ISO Standard 3219
Deviations:
no
GLP compliance:
yes (incl. QA statement)
Type of method:
rotational viscometer (dynamic)

Test material

Constituent 1
Chemical structure
Reference substance name:
Isosorbide Diesters
EC Number:
700-073-5
Cas Number:
1215036-04-6
Molecular formula:
As it is an UVCB, we can not provide the exact molecular formula.
IUPAC Name:
Isosorbide Diesters
Details on test material:
Identification : ISOSORBIDE DIESTERS
Identification of the flask : ROQUETTE isosorbide diesters,
lot Fal/07/25, LAB. 3822, Réf. 806297
Batch : Fal/07/25
Supplier : ROQUETTE
Appearance : Colourless limpid liquid
Packaging : 1 White plastic flask and a transparent soft plastic flask
Quantity received : 1 x 1,2 L and 1 x 3 Kg
Date of the reception : May 30, 2007
July 09, 2008
Storage : In darkness at room temperature
Identification number for the study : 07-066

Results and discussion

Viscosityopen allclose all
Temp.:
20°C
Parameter:
dynamic viscosity (in mPa s)
Value:
>= 67.6 - <= 73.4
Temp.:
40°C
Parameter:
dynamic viscosity (in mPa s)
Value:
>= 22.9 - <= 24.5

Applicant's summary and conclusion

Conclusions:
The mean dynamic viscosity of the test item at 20.0 °C was situated between 67.6 and 73.4 mPa.s (deviation of temperature: ± 0.2 °C).
The mean dynamic viscosity of the test item at 40.0 °C was situated between 22.9 and 24.5 mPa.s (deviation of temperature: ± 0.2 °C).
Taking into account the results obtained at 20.0 and 40.0 °C, the test item was considered to have newtonian properties in our experimental conditions.
Executive summary:

Viscosity of the isosorbide diesters.

Test objective

The objective of the test is to determine the dynamic viscosity of the test item.

Method

Apparatus

Viscometer Multi-Visc Fungilab with LCP spindle

Viscosity

The test item was filled in the test vessel. Two tested temperatures were chosen: 20.0 and 40.0 °C. At regular intervals, the dynamic viscosity of test item was automatically measured. The determination of the test item dynamic viscosity was considered to be completed when a plateau was reached. The whole procedure was carried out in duplicate.

Quality criteria for the viscosity test

The temperature of the test was maintained constant with a tolerance of ± 0.2 °C.

Results

The results of the dynamic viscosity measurements are explained as a function of the rotation speed. The viscosity of the test item appeared to be low, for this reason the mobile LCP (adapted for low viscosity) was chosen.

Conclusion

The mean dynamic viscosity of the test item at 20.0 °C was situated between 67.6 and 73.4 mPa.s

(deviation of temperature: ± 0.2 °C).

The mean dynamic viscosity of the test item at 40.0 °C was situated between 22.9 and 24.5 mPa.s

(deviation of temperature: ± 0.2 °C).

Taking into account the results obtained at 20.0 and 40.0 °C, the test item was considered to have newtonian properties in our experimental conditions.