Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Physical & Chemical properties

Oxidising properties

Currently viewing:

Administrative data

Link to relevant study record(s)

Referenceopen allclose all

Endpoint:
oxidising gases
Data waiving:
study technically not feasible
Justification for data waiving:
the study does not need to be conducted because the substance is a liquid
Endpoint:
oxidising liquids
Data waiving:
study technically not feasible
Justification for data waiving:
the study does not need to be conducted for organic peroxides
Endpoint:
oxidising solids
Data waiving:
study technically not feasible
Justification for data waiving:
the study does not need to be conducted because the substance is a liquid

Description of key information

The test is not applicable for organic peroxides. In the CLP regulations Organic peroxides are not oxidizers. They are classified in a distinct hazard class.
See also ECHA guidance on the application of the CLP criteria, section 2.14.

Key value for chemical safety assessment

Oxidising properties:
non oxidising

Additional information

Oxidising gases


The test item is a liquid at ambient conditions. This hazard class is only applicable for gases. Thus, the substance was not considered for classification as oxidising gases.


Oxidising liquids


The test item is a liquid organic peroxide classified as Org. Peroxide Type C. The test on oxidising liquids is, therefore, not technically feasible.


Oxidising solids


The test item is a liquid at ambient conditions. This hazard class is only applicable for solids. Thus, the substance was not considered for classification as oxidising solid.

Justification for classification or non-classification

Classification, Labelling, and Packaging Regulation (EC) No. 1272/2008


Based on the reasons indicated above the test substance is not classified and labelled with respect to oxidising properties according Regulation (EC) No 1272/2008 (CLP), as amended for the eighteenth time in Regulation (EU) 2022/692.