Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Environmental fate & pathways

Adsorption / desorption

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
adsorption / desorption: screening
Type of information:
experimental study
Adequacy of study:
key study
Study period:
11 February 2011 – 27 April 2011
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
other: This study has been performed according to OECD and EC guidelines and in compliance with GLP principles.
Qualifier:
according to guideline
Guideline:
OECD Guideline 121 (Estimation of the Adsorption Coefficient (Koc) on Soil and on Sewage Sludge using High Performance Liquid Chromatography (HPLC))
Version / remarks:
(2001)
Deviations:
no
Qualifier:
according to guideline
Guideline:
EU Method C.19 (Estimation of the Adsorption Coefficient (KOC) on Soil and Sewage Sludge Using High Performance Liquid Chromatography (HPLC))
Version / remarks:
(Official Journal of the European Union no. L142, May 31, 2008)
Deviations:
no
GLP compliance:
yes (incl. QA statement)
Type of method:
HPLC estimation method
Media:
soil/sewage sludge
Radiolabelling:
no
Test temperature:
35°C +/- 1°C
Details on study design: HPLC method:
Analytical conditions
Instrument: Alliance Separation Module 2695 (Waters, Milford, MA, USA)
Detector: Dual λ Absorbance Detector 2487 (Waters)
Column: Hypersil BDS-CN, 150 mm x 4.6 mm i.d., dp = 5 μm (Thermo Fisher Scientific, Waltham, MA, USA)
Column temperature: 35°C +/- 1°
Mobile phase: 55/45 (v/v) methanol/water
Flow: 1 ml/min
Injection volume: 10 μl
UV detection: 210 nm

E-C104 is a complex mixture of a range of poly substituted organic salt compounds. Therefore, the test was performed at neutral pH.

Type:
Koc
Value:
< 18 dimensionless
Temp.:
35 °C
Remarks on result:
other: HPLC estimation method
Key result
Type:
log Koc
Value:
< 1.3 dimensionless
Temp.:
35 °C
Remarks on result:
other: HPLC estimation method
Details on results (HPLC method):
In the chromatogram of the test substance solution, one peak with a retention time of 1.11 minutes was observed. Under the same analytical conditions, the retention time of acetanilide (log Koc = 1.26) was 2.28 minutes. Hence, it was concluded that the log Koc of test substance was < 1.3 (Koc < 18).
Validity criteria fulfilled:
yes
Conclusions:
The HPLC method using soil-adsorption-reference data was applied for the determination of the adsorption coefficient (Koc) of E-C104.
The Koc and log Koc values of the test substance at neutral pH were < 18 and < 1.3, respectively.

Description of key information

Key value for chemical safety assessment

Koc at 20 °C:
18

Additional information