Administrative data

First-aid measures

Description of first aid measures
General advice
Consult a physician. Show this safety data sheet to the doctor in attendance.
If inhaled
If breathed in, move person into fresh air. If not breathing, give artificial respiration. Consult a physician.
In case of skin contact
Wash off with soap and plenty of water. Take victim immediately to hospital. Consult a physician.
In case of eye contact
Rinse thoroughly with plenty of water for at least 15 minutes and consult a physician.
If swallowed
Do NOT induce vomiting. Never give anything by mouth to an unconscious person. Rinse mouth with water.
Consult a physician.
Most important symptoms and effects, both acute and delayed
Warning: intolerance for alcohol can occur up to 4 days after dimethylformamide exposure. N,Ndimethylformamide
is considered to be a potent liver toxin., Vomiting, Diarrhoea, Abdominal pain, To the best
of our knowledge, the chemical, physical, and toxicological properties have not been thoroughly investigated.
Indication of any immediate medical attention and special treatment needed
no data available

Fire-fighting measures

Extinguishing media
Suitable extinguishing media
For small (incipient) fires, use media such as "alcohol" foam, dry chemical, or carbon dioxide. For large fires,
apply water from as far as possible. Use very large quantities (flooding) of water applied as a mist or spray;
solid streams of water may be ineffective. Cool all affected containers with flooding quantities of water.
Special hazards arising from the substance or mixture
Carbon oxides, nitrogen oxides (NOx)
Advice for firefighters
Wear self contained breathing apparatus for fire fighting if necessary.
Further information
Use water spray to cool unopened containers.

Accidental release measures

Personal precautions, protective equipment and emergency procedures
Wear respiratory protection. Avoid breathing vapors, mist or gas. Ensure adequate ventilation. Remove all
sources of ignition. Evacuate personnel to safe areas. Beware of vapours accumulating to form explosive
concentrations. Vapours can accumulate in low areas.
Environmental precautions
Prevent further leakage or spillage if safe to do so. Do not let product enter drains.
Methods and materials for containment and cleaning up
Contain spillage, and then collect with an electrically protected vacuum cleaner or by wet-brushing and
place in container for disposal according to local regulations.
Reference to other sections

Handling and storage

Precautions for safe handling
Avoid exposure - obtain special instructions before use.Avoid contact with skin and eyes. Avoid inhalation of
vapour or mist.
Keep away from sources of ignition - No smoking.Take measures to prevent the build up of electrostatic
charge.
Conditions for safe storage, including any incompatibilities
Store in cool place. Keep container tightly closed in a dry and well-ventilated place. Containers which are
opened must be carefully resealed and kept upright to prevent leakage.
Handle and store under inert gas.
Specific end uses
no data available

Transport information

Land transport (UN RTDG/ADR/RID)

UN number:
2265
Shippingopen allclose all
SpecialProvisionsopen allclose all
Shippingopen allclose all
Remarksopen allclose all

Marine transport (UN RTDG/IMDG)

UN number:
2265
Shipping information
Proper shipping name and description:
N,N-dimethylformamide
Chemical name:
N,N-dimethylformamide
Remarksopen allclose all

Air transport (UN RTDG/ICAO/IATA)

UN number:
IATA: 2265
Shipping information
Proper shipping name and description:
N,N-dimethylformamide
Chemical name:
N,N-dimethylformamide
Remarksopen allclose all
SpecialProvisionsopen allclose all

Exposure controls / personal protection

Appropriate engineering controls
Avoid contact with skin, eyes and clothing. Wash hands before breaks and immediately after handling the
product.
Personal protective equipment
Eye/face protection
Face shield and safety glasses Use equipment for eye protection tested and approved under
appropriate government standards such as NIOSH (US) or EN 166(EU).
Skin protection
Handle with gloves. Gloves must be inspected prior to use. Use proper glove removal technique
(without touching glove's outer surface) to avoid skin contact with this product. Dispose of
contaminated gloves after use in accordance with applicable laws and good laboratory practices.
Wash and dry hands.
The selected protective gloves have to satisfy the specifications of EU Directive 89/686/EEC and the
standard EN 374 derived from it.
Body Protection
Complete suit protecting against chemicals, Flame retardant antistatic protective clothing, The type
of protective equipment must be selected according to the concentration and amount of the
dangerous substance at the specific workplace.
Respiratory protection
Where risk assessment shows air-purifying respirators are appropriate use a full-face respirator with
multi-purpose combination (US) or type ABEK (EN 14387) respirator cartridges as a backup to
engineering controls. If the respirator is the sole means of protection, use a full-face supplied air
respirator. Use respirators and components tested and approved under appropriate government
standards such as NIOSH (US) or CEN (EU).

Stability and reactivity

Reactivity
no data available
Chemical stability
no data available
Possibility of hazardous reactions
no data available
Conditions to avoid
Heat, flames and sparks.
Incompatible materials
Strong oxidizing agents
Hazardous decomposition products
Other decomposition products - no data available

Disposal considerations

Waste treatment methods
Product
Burn in a chemical incinerator equipped with an afterburner and scrubber but exert extra care in igniting as
this material is highly flammable. Offer surplus and non-recyclable solutions to a licensed disposal
company. Contact a licensed professional waste disposal service to dispose of this material.
Contaminated packaging
Dispose of as unused product.